journal article·2022-01-01Open access

Ion transmission probability through quadrupole mass filter depending on initial ion condition and rod misalignment

Kyu-Ha Jang, Sangyoon Bae, Ju Woo, Sung-Won Kang, Nam-Seok Lee, Young Uk Jeong

AIP Advances· Volume 12· Issue 1

Abstract

A quadrupole mass filter consists of four equidistant parallel rods. Each opposing rod pair is connected electrically, and direct current (DC) and radio frequency alternating current (AC) potentials are applied between one pair of rods and the other. For specific combinations of AC and DC potentials, only ions with a particular mass-to-charge ratio will have a stable trajectory and pass through the quadrupole. Other ions collide with the rods and are not transmitted. The mass filtering is entirely based on the stability of the trajectory of the ions inside the quadrupole. Despite its simple physical geometry and obvious mass separating principle, it is very difficult to analyze the ion behavior in the device even if there is a small deviation from ideal operating conditions. In this paper, the ion transmission probabilities through a quadrupole were calculated using computer simulation at various initial ion conditions and quadrupole mechanical misalignment. The results of this study mainly show the allowable error for quadrupole design, which can be used in improving the performance of the quadrupole mass filter.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Particle accelerators and beam dynamics · Microfluidic and Capillary Electrophoresis Applications · Mass Spectrometry Techniques and Applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Radiation Center for Ultrafast Science, Korea Atomic Energy Research Institute 1 , Daejeon 34057, Republic of Korea

Young in Ace 2 , 1F, 60, Anyangcheondong-ro, Dongan-gu, Anyang-si, Gyeonggi-do 14042, Republic of Korea

Funding

Korea Government

References (22)

Show source-provided references
1. Phys. Rev. · 1918 · 11 · 31610.1103/physrev.11.316 ↗
2. Z. Naturforsch. · 1953 · 8 · 44810.1515/zna-1953-0710 ↗
3. German Patent · 28 1956
4. Rev. Mod. Phys. · 1990 · 62 · 53110.1103/revmodphys.62.531 ↗
5. Phys. Rev. · 1952 · 88 · 119010.1103/physrev.88.1190 ↗
6. Ann. Phys. · 1958 · 3 · 110.1016/0003-4916(58)90012-5 ↗
7. Phys. Rev. · 1952 · 88 · 119710.1103/physrev.88.1197 ↗
8. 1995
9. 1982
10. J. Math. Pures Appl. · 1868 · 13 · 137
11. Am. J. Phys. · 1996 · 64 · 3910.1119/1.18290 ↗
12. IEE Proc.: Sci., Meas. Technol. · 1996 · 143 · 7110.1049/ip-smt:19960128 ↗
13. J. Chem. Educ. · 1998 · 75 · 104910.1021/ed075p1049 ↗
14. 1988
15. J. Anal. At. Spectrom. · 1993 · 8 · 110.1039/ja9930800001 ↗
16. Anal. Chem. · 2008 · 80 · 445510.1021/ac8006945 ↗
17. Clin Biochem Rev · 2019 · 40 · 11510.33176/aacb-19-00024 ↗
18. Rev. Sci. Instrum. · 1954 · 25 · 48510.1063/1.1771107 ↗
19. J. Vac. Sci. Technol. · 1971 · 8 · 26610.1116/1.1316304 ↗
20. Z. Phys. · 1961 · 164 · 58810.1007/bf01378433 ↗
21. Int. J. Mass Spectrom. Ion Phys. · 1969 · 3 · 110.1016/0020-7381(69)80054-9 ↗
22. Rev. Sci. Instrum. · 1999 · 70 · 356610.1063/1.1149960 ↗