A local over-thermal fault evaluation method for C5F10O insulated power equipment based on DWT and BP neural network optimized by GA
Source abstract
Abstract
Due to the growing problem of global warming, C5F10O is promising to replace SF6 as an insulation medium in power equipment because of its low global warming potential and excellent insulation performance and thus has a wide application prospect in the electrical engineering field. Local over-thermal fault is one of the most severe faults in power equipment and has a close relationship with the characteristic decomposition components (CDCs). This paper is devoted to proposing an evaluation method for local over-thermal fault by analyzing CDCs. The discrete wavelet transformation method was adopted to recognize CDC (CF2, CF2CF2, COCF2, and CFCF3) from their variation curves, and the fault feature vector was extracted based on the analysis of frequency band energy. The back propaganda neural network optimized by the genetic algorithm was employed to evaluate the severity of local over-thermal fault with a high accuracy. This work can lay a theoretical basis for local over-thermal fault evaluation based on CDCs in environmentally friendly power equipment.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation · Advanced Sensor and Control Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electrical Engineering, Xi’an University of Technology , Xi’an 710048, China
Funding
National Engineering Laboratory for Ultra High Voltage Engineering Technology · Natural Science Basic Research Program of Shaanxi Province
References (11)
Show source-provided references
1. The sensitivity of C4F7N to electric field and its influence to environment-friendly insulating gas mixture C4F7N/CO210.1088/1361-6463/abbc97 ↗
2. Review of decomposition characteristics of eco-friendly gas insulating medium for high-voltage gas-insulated equipment10.1088/1361-6463/ac04e4 ↗
3. Partial discharge recognition through an analysis of SF6 decomposition products part 1: Decomposition characteristics of SF6 under four different partial discharges10.1109/tdei.2012.6148499 ↗
4. The influence of Cu, Al, and Fe free metal particles on the insulating performance of SF6 in C-GIS10.1109/tdei.2017.006343 ↗
5. Decomposition mechanism of C5F10O: An environmental friendly insulation medium10.1021/acs.est.7b02419 ↗
6. Decomposition properties of C4F7N/N2 gas mixture: An environmentally friendly gas to replace SF610.1021/acs.iecr.8b00010 ↗
7. The decomposition pathways of SF6 in the presence of organic insulator vapors10.1007/s11090-019-10055-0 ↗
8. Feature extraction of SF6 thermal decomposition characteristics to diagnose overheating fault10.1049/iet-smt.2014.0308 ↗
9. Effect of oxygen and temperature on thermal decomposition characteristic of C4F7N/CO2/O2 gas mixture for MV equipment10.1109/access.2020.3043334 ↗
10. Over thermal decomposition characteristics of C5F10O: An environmental friendly insulation medium10.1109/ACCESS.2019.2915382 ↗
11. Application of complex wavelet transform to suppress white noise interference in GIS PD signals10.13334/j.0258-8013.pcsee.2005.16.006 ↗