Water pumping performance of a Cryo–TMP combination pump
Source abstract
Abstract
There is an increasing need to systematically investigate the performance of commercial Cryo–TMP [in-line Cryogenic Water Pump (CWP) + Turbo Molecular Pump (TMP)] combination pumps. In this study, the factors affecting the pumping speed of water in a Cryo–TMP, such as the number of cold rings, dimensions, shape, etc., are systematically analyzed by Monte Carlo simulation. We constructed a test dome and a Cryo–TMP500 based on the simulation results to measure the strict effective pumping performance of the Cryo–TMP. In addition, we established a systematic measurement method for pumping performance using the Cryo–TMP500 in three experimental modes: TMP-only mode, CWP-off mode, and CWP-on mode. The results show that the water pumping speed of the Cryo–TMP500 with only one cold ring is ∼76% of that of a standalone cryopump (∼30 000 L/s) with the same opening inlet diameter; this speed is 22 550 L/s, which is in good agreement with the simulation result of 23 276 L/s. The pumping speeds for non-condensable gases (H2, N2) are 8%–19% higher than expected.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Membrane Separation and Gas Transport · Spacecraft and Cryogenic Technologies · Physics of Superconductivity and Magnetism
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Hyunmin GVT, Inc. 1 , 64, Sandan-ro 197beon-gil, Pyeongtaek-si, Gyeonggi-do 17749, South Korea
BK21 Physics Research Division, Sungkyunkwan University 2 , Suwon-si, Gyeonggi-do 16419, South Korea
Fusion Engineering Division, KAERI 3 , Daejeon 34057, South Korea
References (15)
Show source-provided references
1. 1989
2. J. Vac. Sci. Technol., A · 1989 · 7 · 336110.1116/1.576151 ↗
3. J. Vac. Sci. Technol., A · 1994 · 12 · 177210.1116/1.579004 ↗
4. J. Vac. Sci. Technol., A · 1995 · 13 · 46710.1116/1.579381 ↗
5. 1997
6. J. Phys.: Condens. Matter · 2009 · 21 · 20210110.1088/0953-8984/21/20/202101 ↗
7. A review of outgassing and methods for its reduction10.5757/ASCT.2017.26.5.95 ↗
8. J. Vac. Sci. Technol., A · 1983 · 1 · 15010.1116/1.572062 ↗
9. Recent developments of Monte-Carlo codes MolFlow+ and SynRad+
10. J. Vac. Sci. Technol., A · 1998 · 16 · 349510.1116/1.581509 ↗
11. J. Vac. Sci. Technol., A · 1983 · 1 · 13610.1116/1.572058 ↗
12. Vacuum · 1996 · 47 · 77910.1016/0042-207x(96)00065-6 ↗
13. Fusion Eng. Des. · 2001 · 58-59 · 44510.1016/s0920-3796(01)00487-2 ↗
14. M. Ady and R. Kersevan, “Recent developments of Monte-Carlo codes MolFlow+ and SynRad+,” in 10th International Particle Accelerator Conference, Melbourne, Australia, 2019, http://www.jacow.org.
15. R. Grinham and A. Chew (2017). “A review of outgassing and methods for its reduction,” ASCT, Dataset. 10.5757/ASCT.2017.26.5.9510.5757/ASCT.2017.26.5.95 ↗