A quantitative diagnosis using magnetic resonance imaging (MRI) can be disturbed by radiofrequency (RF) field inhomogeneity induced by the conductive implants. This inhomogeneity causes a local decrease of the signal intensity around the conductor, resulting in a deterioration of the accurate quantification. In a previous study, we developed an MRI imaging method using a two-dimensional selective excitation pulse (2D pulse) to mitigate signal inhomogeneity induced by metallic implants. In this paper, the effect of 2D pulse was evaluated quantitatively by numerical simulation and MRI experiments. We introduced two factors for evaluation, spatial resolution and maximum compensation factor. Numerical simulations were performed with two groups. One group was composed of four models with different signal loss width, to evaluate the spatial resolution of the 2D pulse. The other group is also composed of four models with different amounts of signal loss for evaluating maximum compensation factor. In MRI experiments, we prepared phantoms containing conductors, which have different electrical conductivities related with the amounts of signal intensity decrease. The recovery of signal intensity was observed by 2D pulses, in both numerical simulations and experiments.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Advanced MRI Techniques and Applications · Microwave Imaging and Scattering Analysis · Electrical and Bioimpedance Tomography

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

The University of Tokyo Department of Electrical Engineering and Information Systems, Graduate School of Engineering, , Tokyo, 113-0032, Japan

Funding

Japan Society for the Promotion of Science · Japan Science and Technology Agency

References (13)

Show source-provided references
1. RF artifacts caused by metallic implants or instruments which get more prominent at 3 T: An in vitro study10.1016/j.mri.2004.12.009 ↗
2. Mapping B 1-induced eddy current effects near metallic structures in MR images: A comparison of simulation and experiment10.1016/j.jmr.2014.10.016 ↗
3. Quantitative evaluation of metal artifact reduction techniques10.1002/jmri.20144 ↗
4. A quantitative study of the pixel-shifting, blurring and nonlinear distortions in MRI images caused by the presence of metal implants10.1117/12.431163 ↗
5. SQUID-detected in vivo MRI at microtesla magnetic fields10.1109/tasc.2005.850043 ↗
6. Prepolarized magnetic resonance imaging around metal orthopedic implants10.1002/mrm.20927 ↗
7. Reduction of metal artifacts in patients with total hip arthroplasty with slice-encoding metal artifact correction and view-angle tilting MR imaging10.1148/radiol.12112408 ↗
8. MR imaging near metal with undersampled 3D radial UTE-MAVRIC sequences10.1002/mrm.24219 ↗
9. Design of radio frequency pulse waveforms for mitigating signal inhomogeneity in magnetic resonance imaging due to metallic implants10.1063/1.4908298 ↗
10. A k-space analysis of small-tip-angle excitation10.1016/0022-2364(89)90265-5 ↗
11. Spatial domain method for the design of RF pulses in multicoil parallel excitation10.1002/mrm.20978 ↗
12. Spatial excitation using variable-density spiral trajectories10.1002/jmri.10334 ↗
13. 1989 · D-221