journal article·2016-12-01Open access

Resolution enhancement of pump-probe microscopy with an inverse-annular spatial filter

T. Kobayashi, K. Kawasumi, J. Miyazaki, K. Nakata

AIP Advances· Volume 6· Issue 12

Abstract

We have introduced a pupil filter, an inverse-annular pupil filter in a pump-probe photothermal microscope, which provides resolution enhancement in three dimensions. The resolution is probed to be improved in lateral and axial resolution by imaging experiment using 20 nm gold nanoparticles. The improvement in X (perpendicular to the common pump and probe polarization direction), Y (parallel to the polarization direction), and Z (axial direction) are by 15±6, 8±8, and 21±2 % from the resolution without a pupil filter. The resolution enhancement is even better than the calculation using vector field, which predicts the corresponding enhancement of 11, 8, and 6 %. The discussion is made to explain the unexpected results. We also demonstrate the photothermal imaging of thick biological samples (cells from rabbit intestine and kidney) stained with hematoxylin and eosin dye with the inverse-annular filter.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photoacoustic and Ultrasonic Imaging · Advanced Fluorescence Microscopy Techniques · Near-Field Optical Microscopy

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

The University of Electro-Communications 1 Advanced Ultrafast Laser Research Center, , 1-5-1 Chofugaoka, Chofu, Tokyo 182-8585, Japan

CREST 2 JST, , K’ Gobancho, 7, Gobancho, Chiyoda-ku, Tokyo 102-0076, Japan

National Chiao-Tung University 3 Department of Electrophysics, , Hsinchu 300, Taiwan

Osaka University 4 Institute of Laser Engineering, , 2-6 Yamada-oka, Suita, Osaka 565-0971, Japan

References (27)

Show source-provided references
1. Pump-probe imaging of historical pigments used in paintings10.1364/OL.37.001310 ↗
2. Femtosecond pump-probe near-field optical microscopy10.1063/1.1149841 ↗
3. Implementation of intensity-modulated laser diodes in time-resolved diodes in time-resolved, pump-probe fluorescence microscopy10.1364/AO.40.001109 ↗
4. In vivo and ex vivo epi-mode pump-probe imaging of melanin and microvasculature10.1364/BOE.2.001576 ↗
5. Imaging chromophores with undetectable fluorescence by stimulated emission microscopy10.1038/nature08438 ↗
6. Pump-probe optical microscopy for imaging nonfluorescent chromophores10.1007/s00216-012-5890-1 ↗
7. Single metallic nanoparticle imaging for protein detection in cells10.1073/pnas.1534635100 ↗
8. Photothermal microscopy: Optical detection of small absorbers in scattering environments10.1111/jmi.12130 ↗
9. Photothermal heterodyne imaging of individual metallic nanoparticles: Theory versus experiment10.1103/PhysRevB.73.045424 ↗
10. Sub-diffraction resolution pump probe microscopy with shot-noise limited sensitivity using laser diodes10.1364/OE.22.009024 ↗
11. Optimal detection angle in sub-diffraction resolution photothermal microscopy: Application for high sensitivity imaging of biological tissues10.1364/OE.22.018833 ↗
12. Resolution improvement in laser diodes-based pump probe microscopy with an annular pupil filter10.1364/OL.39.004219 ↗
13. Simultaneous dual-wavelength imaging of nonfluorescent tissues with 3D subdiffraction photothermal microscopy10.1364/OE.23.003647 ↗
14. Sensitivity enhancement of photothermal microscopy with radially segmented balanced detection10.1364/OL.40.000479 ↗
15. Reduction of distortion in photothermal microscopy and its application to the high resolution three-dimensional imaging of nonfluorescent tissues10.1364/BOE.6.003217 ↗
16. Orientational imaging of single molecules by annular illumination10.1103/PhysRevLett.85.4482 ↗
17. Demonstration of high lateral resolution in laser confocal microscopy using annular and radially polarized light10.1002/jemt.20689 ↗
18. Sub-wavelength focal spot with long depth of focus generated by radially polarized, narrow-width annular beam10.1364/OE.18.004518 ↗
19. Three-dimensional superresolution by annular binary filters10.1016/S0030-4018(99)00226-6 ↗
20. Tunable axial superresolution by annular binary filters. Application to confocal microscopy10.1016/0030-4018(95)00380-Q ↗
21. Electromagnetic diffraction in optical systems. II. Structure of the image field in an aplanatic system10.1098/rspa.1959.0200 ↗
22. Focusing of high numerical aperture cylindrical-vector beams10.1364/OE.7.000077 ↗
23. 2005
24. Photothermal single-particle microscopy: Detection of a nanolens
25. Fluorescence lifetime imaging of endogenous fluorophores in histopathology sections reveals differences between normal and tumor epithelium in carcinoma in situ of the breast10.1007/s12013-009-9046-7 ↗
26. Fluorescence microscopy of rat embryo sections stained with haematoxylin–eosin and Masson’s trichrome method10.1046/j.1365-2818.1998.00348.x ↗
27. Fluorescence and confocal laser scanning microscopy imaging of elastic fibers in hematoxylin-eosin stained sections10.1007/BF02473274 ↗