journal article·2017-03-01Open access

A noise-resistant ADSA-PH algorithm for superhydrophobic surface’s static contact angle evaluation

Z. N. Xu

AIP Advances· Volume 7· Issue 3

Abstract

The blur around the contact points significantly decreases the evaluated static contact angle for superhydrophobic surface which is clearly presented in the paper. To improve the accuracy in the evaluated static contact angle for superhydrophobic surface, an accurate static contact angle algorithm, namely ADSA-PH (axisymmetric drop shape analysis-profile and height), is proposed. It discards the extracted drop edge points close to the contact points and makes use of the residual points and the drop height to determine the static contact angle. The contact angle errors caused by the blur close to the contact points are significantly reduced. The classical ADSA-P algorithm, the modified selected-plane method and the proposed algorithm are used to evaluate static contact angle. The results validate the proposed algorithm. The accuracy in the evaluated contact angle increases with increasing image resolution. To reduce the error caused by a limitation of image resolution, the minimum allowable image resolutions are presented.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Surface Modification and Superhydrophobicity · Icing and De-icing Technologies · Aerosol Filtration and Electrostatic Precipitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

North China Electric Power University Hebei Provincial Key Laboratory of Power Transmission Equipment Security Defense, , Baoding 071003, China and State Key Laboratory of Alternate Electrical Power System with Renewable Energy Sources, , Baoding 071003, China

References (18)

Show source-provided references
1. Corrosion Science · 2016 · 102 · 25110.1016/j.corsci.2015.10.013 ↗
2. Journal of Colloid and Interface Science · 2016 · 466 · 3610.1016/j.jcis.2015.12.015 ↗
3. Applied Physics Letters · 2016 · 109 · 16160110.1063/1.4964762 ↗
4. Applied Physics Letters · 2016 · 109 · 04370210.1063/1.4959840 ↗
5. Applied Physics Letters · 2013 · 102 · 25160310.1063/1.4812480 ↗
6. Applied Physics Letters · 2012 · 101 · 08160110.1063/1.4747327 ↗
7. AIP Advances · 2016 · 6 · 07521810.1063/1.4960115 ↗
8. Journal of the American Chemical Society · 2004 · 126
9. Soft Matter · 2009 · 510.1039/B811945G ↗
10. Soft Matter · 2008 · 410.1039/B712575P ↗
11. Langmuir · 2010 · 26
12. Review of Scientific Instruments · 2011 · 8210.1063/1.3579498 ↗
13. Review of Scientific Instruments · 2014 · 8510.1063/1.4865118 ↗
14. Micro & Nano Letters · 2014 · 9
15. Langmuir · 2011 · 2710.1021/la2031208 ↗
16. Review of Scientific Instruments · 2010 · 8110.1063/1.3449325 ↗
17. Colloids and Surfaces A: Physicochemical and Engineering Aspects · 2011 · 38810.1016/j.colsurfa.2011.08.001 ↗
18. Langmuir · 2007 · 23