journal article·2024-12-01Open access

Study on factors influencing the unbalance of double-split parallel cable current carrying

Jiayin Bian, Jue Zhang, Huang Yuping, Shaozhen Jiang, Xuan Qiu, Jiayu Mai

AIP Advances· Volume 14· Issue 12

Abstract

In recent years, the transmission capacity of a single high-voltage cable has been unable to meet the growing load demand, and double-split parallel cables have become a necessary treatment to improve the transmission capacity requirements. Among them, due to the complex electromagnetic relationship between cables, it may lead to different current-carrying capacity of the same-phase cable line, and this current imbalance will affect the normal operation of power equipment, and in serious cases, it will threaten the safe operation of the power system. This paper first summarizes the factors that may affect the current imbalance degree and then uses Magnet software to carry out finite element simulation analysis of parallel cables to obtain the current-carrying imbalance degree of each phase and finally obtains the influence factor and sensitivity of the current-carrying imbalance degree through comparative analysis, so as to provide effective help for the laying of cables.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Elevator Systems and Control · Power Systems and Technologies · High-Voltage Power Transmission Systems

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Guangzhou Power Supply Bureau of Guangdong Power Grid Co. Ltd. , Guangzhou 510620,

Funding

Guangzhou Power Grid CO., LTD.

References (19)

Show source-provided references
1. Open-phase resonance in shunt-compensated AC cable lines
2. Study on the induction coupling response characteristics of parallel cables
3. Study on parameter unbalance of 500 kV double circuit cable line considering different arrangement
4. Analysis and treatment of temperature anomaly in parallel operation of excitation AC single-core cables10.3969/j.issn.1006-348X.2022.06.003 ↗
5. Analysis and treatment of temperature anomaly when multiple AC excitation cables are connected in parallel in the same phase10.3969/j.issn.1006-348X.2022.04.002 ↗
6. Study on parallel current flow characteristics of AC high-voltage single-core cables for offshore wind power transmission
7. Analysis and solution of the current deviation problem when single-core cables are used in parallel in steel plants
8. Parameter optimization of cable group layout based on machine vision10.19557/j.cnki.1001-9944.2022.01.020 ↗
9. Applicability analysis of distance protection applied to common-phase parallel cables10.19783/j.cnki.pspc.200269 ↗
10. Analysis of phase-to-phase short circuit fault cases of parallel single-core medium-voltage power cables
11. Optimization strategy for parallel operation of multiple cables in the same phase for gas generator sets
12. Research of parallel placed submarine cable route detection method
13. Research on 110 kV power cable sheath voltage simulation and compensation
14. Analysis of induced voltage on long high-voltage cable sheath based on ANSYS
15. Suppression measures for overvoltage of single-core cable sheath caused by harmonics and inrush current
16. Analysis and calculation of circulating leakage current components of high voltage cable sheath10.19457/j.1001-2095.dqcd24621 ↗
17. Calculation and analysis of circulating current in metal sheath of single-core power cable10.19768/j.cnki.dgjs.2021.19.039 ↗
18. Simulation analysis of circulating current characteristics of high voltage cable sheath under mixed arrangement mode10.19718/j.issn.1005-2992.2023-02-0025-07 ↗
19. High-voltage cable metal sheath circulation suppression method based on short-circuit current guidance and its influence factors analysis