Absolute magneto-optical measurement of magnetic field on a long pulse high electrical current driven solenoid
Source abstract
Abstract
We describe a direct absolute magneto-optical approach to measuring the magnetic field driven by long pulse width (>5 ms) and high electrical current (∼kA) in a solenoidal coil. The magnetic field and electrical current are among the most important operating parameters in lightning research and electrical power distribution and are essential to understanding the properties of the radiation output in pulsed energy accelerators as well as other research platforms. However, accurately measuring these magnetic fields and electrical currents using conventional electrical diagnostics is difficult due to the strength of ionizing radiation and electromagnetic interference. Our approach uses a fiber coupled laser beam with a rare earth element material sensing crystal that is highly resistant to electromagnetic interference, allows for absolute measurement, and does not require an external calibration. Here, we focus on device theory, operating parameters, magneto-optical results from an experiment on a high current solenoid, and comparison with a calculation of the magnetic field and reference electrical current flowing downstream of the solenoid.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magneto-Optical Properties and Applications · Ionosphere and magnetosphere dynamics · Gyrotron and Vacuum Electronics Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Sandia National Laboratories , Albuquerque, New Mexico 87123,
References (12)
Show source-provided references
1. B-dot and D-dot sensors for (sub)nanosecond high-voltage and high-current pulse measurements10.1109/JSEN.2016.2530841 ↗
2. Differential-output B-dot and D-dot monitors for current and voltage measurements on a 20 MA, 3 MV pulsed-power accelerator10.1103/PhysRevSTAB.11.100401 ↗
3. A metal-foil shunt for measuring sub-microsecond duration high current pulses10.1088/0022-3735/3/11/306 ↗
4. Appl. Opt. · 1978 · 17 · 5210.1364/ao.17.000052 ↗
5. Fiber-optic sensing of pulsed currents10.1117/12.964535 ↗
6. Advances in optical fiber-based Faraday rotation diagnostics
7. Electro-optical measurement of electric fields for pulsed power systems
8. Electro-optical measurement of intense electric field on a high energy pulsed power accelerator10.1038/s41598-021-89851-8 ↗
9. Magneto-optical measurement of magnetic field and electrical current on a short pulse high energy pulsed power accelerator10.1063/5.0171543 ↗
10. Applications of magneto-strictive, magneto-optical, magnetic fluid materials in optical fiber current sensors and optical fiber magnetic field sensors: A review10.1016/j.yofte.2021.102634 ↗
11. Pulsed-coil magnet systems for applying uniform 10–30 T fields to centimeter-scale targets on Sandia’s Z facility10.1063/1.4902566 ↗
12. Verdet constant of magneto-active materials developed for high-power Faraday devices10.3390/app9153160 ↗