Research on splicing method of temperature distribution curve of EHV–UHV long string porcelain insulators
Source abstract
Abstract
The infrared thermal image detection method has unique advantages in the field of low zero value diagnosis of porcelain insulators. However, since the length of the extra–ultra-high voltage (EHV–UHV) porcelain insulator string can reach more than 10 m, it is difficult for common industrial thermal imagers/airborne lenses to clearly capture the infrared spectrum of the full string of EHV–UHV porcelain insulators. In order to solve this problem, this paper proposes a two-segment temperature curve splicing method based on weighted data fusion. The method avoids the problem of missing targets existing in conventional infrared image splicing methods and has higher fitting accuracy than curve splicing methods such as rounding splicing and midpoint splicing. This paper takes a 1000 kV insulator string as an example to illustrate the basic algorithm and process of the proposed curve splicing method and takes a 500 kV insulator string as an example to carry out a comparative study of various curve splicing methods, which verifies the effectiveness and feasibility of the proposed method.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Image Enhancement Techniques · Advanced Neural Network Applications · Power Line Inspection Robots
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Grid Hubei Electric Power Co., Ltd., Electric Power Research Institute , Wuhan, Hubei 430077, China
Funding
The Science and Technology Guide Project of State Grid Corporation of China
References (8)
Show source-provided references
1. Failure analysis of decay-like fracture of composite insulator10.1109/TDEI.2014.004485 ↗
2. Decay-like fracture mechanism of silicone rubber composite insulator10.1109/tdei.2018.006773 ↗
3. Effect of moisture on temperature rise of composite insulators operating in power system10.1109/TDEI.2015.004696 ↗
4. Moisture induced local heating of overhead line composite insulators10.1109/TDEI.2016.005791 ↗
5. Characterization of polymeric insulators using thermal and UV imaging under laboratory conditions10.1109/tdei.2009.5211844 ↗
6. Aggregating deep convolutional feature maps for insulator detection in infrared images10.1109/access.2017.2757030 ↗
7. Heating phenomenon in unclean composite insulators10.1016/j.engfailanal.2016.03.016 ↗
8. Analysis on heat source of abnormal temperature rise of composite insulator housings10.1109/TDEI.2017.006929 ↗