The study of neutron sensitivity of the MCP based on recoil proton detection
Source abstract
Abstract
A new neutron detector based on a recoil proton and a microchannel plate (MCP) has been developed for the measurement of ultrafast pulse neutrons. In order to know the performance of the detector, the neutron sensitivity was investigated through simulation and experiment. A model of Monte Carlo simulation was set up for neutron sensitivity simulation. In this model, the yields and average energy of protons emitted from polyethylene targets of different thicknesses were calculated as a function of neutron energy. Then, the yields of secondary electrons produced by the recoil protons in the microchannel of the MCP were also calculated. The neutron sensitivity of the detector was finally obtained. The results show that the detector can achieve a neutron sensitivity of more than 10−15 C cm2 if the neutron energy is greater than 1 MeV. Experiments were performed to test the neutron sensitivity on the accelerator at the China Institute of Atomic Energy. The simulated results agreed with those of the experiments considering the uncertainties. The theoretical model of the detector for the calculation of the neutron sensitivity was correct. The performance of the detector accorded with the anticipative purpose.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Radiation Therapy and Dosimetry · Radiation Detection and Scintillator Technologies · Nuclear Physics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology , No. 28, Pingyu Road, Xi’an 710024, China
Funding
Northwestern Institute of Nulcear Technology · National Natural Science Foundation of China
References (13)
Show source-provided references
1. Research on X ray characteristics produced by high energy picosecond electron beam shooting
2. Development of photo-neutron facility driven by electron LINAC10.11889/j.0253-3219.2014.hjs.37.100522 ↗
3. Micro-channel plates and vacuum detectors10.1016/j.nima.2014.12.044 ↗
4. Fast rise time, high sensitivity MCP ion detector for low-energy ion spectroscopy10.1088/0022-3735/22/6/011 ↗
5. Measurement of MCP-PMT’s linear output for narrow intensive pulse based on waveform comparison method10.7538/yzk.2016.50.03.0553 ↗
6. Dante soft x-ray power diagnostic for national ignition facility10.1063/1.1788872 ↗
7. 2001
8. SRIM-200310.1016/j.nimb.2004.01.208 ↗
9. SRIM—The stopping and range of ions in matter10.1016/j.nimb.2010.02.091 ↗
10. Analysis of secondary electron emission properties of MgO/Au composite film with an Al-doped MgO surface layer10.1063/1.5051803 ↗
11. Deuteron induced secondary electron emission from titanium deuteride surface10.1016/j.nimb.2012.02.033 ↗
12. Monte Carlo study of ion-induced backward and forward secondary electron emission from thin Al foil10.1016/j.nimb.2007.12.059 ↗
13. 2006