journal article·2020-06-01Open access

Ion current collection by double flush-mounted probe in intermediate-pressure plasmas

Pengcheng Yu, Yu Liu, Yiming Ling, Zhongkai Zhang, Jinxiang Cao, Jiuhou Lei, Xiao Zhang

AIP Advances· Volume 10· Issue 6

Abstract

A double flush-mounted probe method is proposed to analyze the characteristics of intermediate-pressure plasmas (10–100 Pa) by a sheath criterion. The analytical model mainly focuses on the effect of the ion drift velocity in the sheath edge and then provides a correction factor for the measured ion-collection current. The reduction of the ion current is attributed to ion–neutral collisions leading to the modified Bohm velocity. To validate this method, the ion density is calculated and compared with that measured by two types of cylindrical probes, and the results agree well with the data measured by other probes. On the basis of this work, the double flush-mounted probe can be adopted to diagnose plasma parameters accurately, without a reference electrode, in collisional and certain complex plasma environments, such as the reentry plasma sheath.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Plasma Diagnostics and Applications · Magnetic confinement fusion research · Metal and Thin Film Mechanics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

CAS Key Laboratory of Geospace Environment, Department of Engineering and Applied Physics, University of Science and Technology of China 1 , Hefei, Anhui 230026, China

CAS Key Laboratory of Geospace Environment, School of Earth and Space Sciences, University of Science and Technology of China 2 , Hefei, Anhui 230026, China

CAS Center for Excellence in Comparative Planetology 3 , Hefei 230026, China

Key Laboratory of Optoelectronic Devices and Systems of Ministry of Education and Guangdong Province, College of Optoelectronic Engineering, Shenzhen University 4 , Shenzhen, Guangdong 518060, People’s Republic of China and , P.O. Box 1126, Hefei, Anhui 230031, People’s Republic of China

Institute of Plasma Physics, Chinese Academy of Sciences 4 , Shenzhen, Guangdong 518060, People’s Republic of China and , P.O. Box 1126, Hefei, Anhui 230031, People’s Republic of China

Funding

The B-Type Strategic Priority Program of the Chinese Academy of Sciences · The KSPEX Device Was Supported by the Grants From NSFC · The USTC Research Funds of the Double First-Class Initiative · The China Postdoctoral Science Foundation of China · The Pre-Research Project on Civil Aerospace Technologies · The Fundamental Research Funds for the Central Universities · Youth Innovation Promotion Association

References (29)

Show source-provided references
1. Langmuir probe characterization of laser ablation plasmas10.1063/1.3056131 ↗
2. Langmuir probe analysis of highly electronegative plasmas10.1063/1.4802252 ↗
3. Effect of charge exchange ions upon Langmuir probe current10.1063/1.1506946 ↗
4. Langmuir probe analysis for high density plasmas10.1063/1.1368874 ↗
5. High voltage plume measurements and internal probing of the BHT-1000 hall thruster
6. Near-wall plasma properties and EEDF measurements of a 6-kW hall thruster
7. Flush-mounted probes in the divertor plates of Tokamak de Varennes10.1063/1.1145249 ↗
8. Tokamak plasma diagnosis by electrical probes10.1088/0741-3335/36/10/002 ↗
9. Operation of flush-mounted probes in the Tdev tokamak10.1063/1.1147840 ↗
10. Boundary-layer ion density profiles as measured by electrostatic probes10.2514/3.3912 ↗
11. Experimental and numerical studies of flush electrostatic probes in hypersonic ionized flows: I. Experiment10.2514/3.50408 ↗
12. A floating double probe method for measurement in gas discharge10.1103/physrev.80.58 ↗
13. Investigation of the fluxes to a surface at grazing angles of incidence in the tokamak boundary10.1088/0741-3335/32/14/004 ↗
14. Electrical probe diagnostics for the laminar flame quenching distance10.1016/j.expthermflusci.2009.10.002 ↗
15. Sheath criterion and boundary conditions for an electrostatic sheath10.1063/1.872768 ↗
16. Tokamak plasma diagnosis by surface physics techniques
17. 1970
18. Electromagnetic reduction of plasma density during atmospheric reentry and hypersonic flights10.2514/1.32147 ↗
19. Boundary layer diagnostics by means of an infrared scanning radiometer10.1007/bf00187411 ↗
20. Effect of collisions on positive ion collection by a cylindrical Langmuir probe10.1088/0032-1028/16/12/011 ↗
21. Comparison between Langmuir probe and microwave auto interferometry measurements at intermediate pressure in an argon surface wave discharge10.1063/1.2112172 ↗
22. A new method for analyzing Langmuir probe data and the determination of ion densities and etch yields in an etching plasma10.1116/1.576782 ↗
23. Effect of angle of incidence on the response of cylindrical electrostatic probes at supersonic speeds10.2514/3.50282 ↗
24. A contribution to the assessment of the influence of collisions on the measurements with Langmuir probes in the thick sheath working regime10.1007/bf01676361 ↗
25. A study of the accuracy of various Langmuir probe theories10.1063/1.357280 ↗
26. Design and construction of Keda Space Plasma Experiment (KSPEX) for the investigation of the boundary layer processes of ionospheric depletions10.1063/1.4962406 ↗
27. Laboratory generation of broadband ELF waves by inhomogeneous plasma flow10.1002/2016gl072232 ↗
28. Flush-mounted probe diagnostics for argon glow discharge plasma10.1063/1.4895644 ↗
29. Double flush-mounted probe diagnostics and data analysis technique for argon glow discharge plasma10.1063/1.4973701 ↗