Increasing the length of free-falling path with homogeneous bias field for compact cold atom interferometers by configuring MOT coils
Source abstract
Abstract
In a cold atom interferometer, a bias magnetic field, usually generated by a solenoid or a set of coils, is used to select specific Raman transitions of atoms in the interference region, and its inhomogeneity leads to a Zeeman-effect-induced error for the measurement. To improve the measurement’s accuracy further, we propose a simple method to compensate for the non-uniformity of the bias field by reversing the direction and tuning the value of the current running through the pair of quadrupole coils used for magneto-optical trap (MOT). To smoothen the field with MOT coils, the current applied should be controlled timely and precisely, which was done with a fast-responding electric circuit we designed and built. We also used Raman spectroscopy to characterize the magnetic field profile without and with our method applied, which shows that the length of the homogeneous field (where the fluctuation of magnetic strength is less than 10%) is expanded from 81.87 mm to 101.64 mm. From our calculations, with the free evolution time T of 30 ms, the quadratic Zeeman-effect-induced phase shift Δϕzeeman can be reduced by 76%, which reduces the quadratic Zeeman-effect-induced error of measured gravity Δgzeeman to a quarter of that without our method applied (from 1.745 mGal to 0.418 mGal). Simulation and experiment prove that this method is effective. This method can also be used in other atom interferometers, especially compact systems.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Cold Atom Physics and Bose-Einstein Condensates · Atomic and Subatomic Physics Research · Advanced Frequency and Time Standards
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
National University of Defense Technology, College of Artificial Intelligence 1 , Changsha, Hunan 410073, China
National University of Defense Technology, Interdisciplinary Center for Quantum Information 2 , Changsha, Hunan 410073, China
References (29)
Show source-provided references
1. Atom cooling, trapping, and quantum manipulation10.1103/revmodphys.71.s253 ↗
2. High-precision gravity measurements using atom interferometry10.1088/0026-1394/38/1/4 ↗
3. Precision measurement of gravity with cold atoms in an optical lattice and comparison with a classical gravimeter10.1103/physrevlett.106.038501 ↗
4. Sensitive absolute-gravity gradiometry using atom interferometry10.1103/physreva.65.033608 ↗
5. Sensitive gravity-gradiometry with atom interferometry: Progress towards an improved determination of the gravitational constant10.1088/1367-2630/12/9/095009 ↗
6. Absolute geodetic rotation measurement using atom interferometry10.1103/physrevlett.107.133001 ↗
7. Atom interferometer as a selective sensor of rotation or gravity10.1103/physreva.74.023615 ↗
8. High-accuracy optical clock based on the octupole transition in 171Yb+10.1103/physrevlett.108.090801 ↗
9. Colloquium: Physics of optical lattice clocks10.1103/revmodphys.83.331 ↗
10. Determination of the fine structure constant based on BLOCH oscillations of ultracold atoms in a vertical optical lattice10.1103/physrevlett.96.033001 ↗
11. Combination of BLOCH oscillations with a Ramsey-Bordé interferometer: New determination of the fine structure constant10.1103/physrevlett.101.230801 ↗
12. Precision measurement of the Newtonian gravitational constant using cold atoms10.1038/nature13433 ↗
13. Quantum test of the universality of free fall10.1103/physrevlett.112.203002 ↗
14. The investigation of a μGal-level cold atom gravimeter for field applications10.1088/0026-1394/51/5/452 ↗
15. Accurate rubidium atomic fountain frequency standard10.1088/0026-1394/48/3/003 ↗
16. Limits to the symmetry of a Mach-Zehnder-type atom interferometer10.1103/physreva.93.013609 ↗
17. Simultaneous differential measurement of a magnetic-field gradient by atom interferometry using double fountains10.1103/physreva.84.013620 ↗
18. Compact cold atom gravimeter for field applications10.1063/1.4801756 ↗
19. Precisely mapping the magnetic field gradient in vacuum with an atom interferometer10.1103/physreva.82.061602 ↗
20. Magnetic field measurement by weak magnetic-sensitive Zeeman splitting10.1063/1.4918650 ↗
21. Simultaneous precision gravimetry and magnetic gradiometry with a Bose-Einstein condensate: A high precision, quantum sensor10.1103/physrevlett.117.138501 ↗
22. Mapping the absolute magnetic field and evaluating the quadratic Zeeman-effect-induced systematic error in an atom interferometer gravimeter10.1103/physreva.96.033414 ↗
23. Magnetic field measurement based on a stimulated two-photon Raman transition10.1088/1674-1056/20/3/034206 ↗
24. Atom interferometry with up to 24-photon-momentum-transfer beam splitters10.1103/physrevlett.100.180405 ↗
25. Large momentum beam splitter using BLOCH oscillations10.1103/physrevlett.102.240402 ↗
26. Why momentum width matters for atom interferometry with Bragg pulses10.1088/1367-2630/14/2/023009 ↗
27. Development of an atom gravimeter and status of the 10-meter atom interferometer for precision gravity measurement10.1007/s10714-011-1167-9 ↗
28. An improved Helmholtz coil and analysis of its magnetic field homogeneity10.1063/1.1471352 ↗
29. Measurement of the sensitivity function in a time-domain atomic interferometer10.1109/tim.2007.915148 ↗