journal article·2019-02-01Open access

Low-level RF control of a klystron for medical linear accelerator applications

Sun-Hong Min, Ohjoon Kwon, Matlabjon Sattorov, Seontae Kim, Dongpyo Hong, Chawon Park, Bong Hwan Hong, In Su Jung, Ilsung Cho, Won Taek Hwang, Ranjan Kumar Barik, Anirban Bera, Gun-Sik Park

AIP Advances· Volume 9· Issue 2

Abstract

A klystron is an important vacuum device which is useful in medical linear accelerators because it amplifies the radio-frequency (RF) signals required to produce high-energy particle beams. The properties of the nonlinear input and output dynamics in the klystron circuit arouse distortion in various types of parameters pertaining to the beam voltage, beam current, RF power, and operating frequency from unpredictable external factors. Therefore, low-level RF (LLRF) control systems can facilitate the regulation of the output of the klystron to a desired level. Low-level RF control system of the klystron is designed to stabilize the applied voltage and control the resonance frequency of the cavity of the klystron. In this work, an infallible low-level RF control system, the most suitable for a klystron, is designed to use a beam monitoring and an interlock system with components that include an isolator and a phase shifter. Moreover, with regard to pulse distortion at the flap top at the RF output power, the stability of the RF power pulse at the flap top part was improved somewhat by a variable inductor which controlled the inside of the pulse modulator. In this LLRF control experiment, the pulse modulator generated 140kV-95A and succeeded in generating RF output power of 2.856GHz-6MW level of an S-band klystron. During this process, the efficiency of the RF power was approximately 42∼45% and the pulse repetition rate was 10 Hz. The flattop pulse width was measured and found to be 1 µs.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Gyrotron and Vacuum Electronics Research · Pulsed Power Technology Applications · Microbial Inactivation Methods

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Korea Institute of Radiological and Medical Sciences (KIRAMS) 1 , Seoul 01812, South Korea

Center for THz-driven Biomedical Systems, Department of Physics and Astronomy, Seoul National University 2 , Seoul 08826, South Korea

Institute for Basic Science Center for Axion and Precision Physics Research 3 , Daejeon 34141, South Korea

Seoul-Teracom, Inc. 4 , Gyeonggi-do, Suwon 16229, South Korea

The Council of Scientific and Industrial Research, Central Electronics Engineering Research Institute 5 , Pilani 333031, India

Funding

National Research Foundation of Korea · Korea Institute of Radiological and Medical Sciences

References (10)

Show source-provided references
1. 2005
2. 2011 · 95
3. 2008
4. 2012
5. Med. Phys. · 2013 · 40 · 410.1002/j.2473-4209.2013.tb00207.x ↗
6. Phys. Procedia · 2012 · 26 · 22310.1016/j.phpro.2012.03.029 ↗
7. Carli · 2014 · 230
8. Yamazaki · 2016 · 760
9. Arthur · 453
10. Nucl. Instrum. Methods Phys. Res. A · 2013 · 729 · 50610.1016/j.nima.2013.07.057 ↗