journal article·2024-07-01Open access

Influences of the vibration frequency and phase of the core of ultra-high voltage shunt reactors on suspended discharge in oil-paper insulation

Hua Yu, Hong Liu, Shuai Li, Jizhong Liang, Shu Niu

AIP Advances· Volume 14· Issue 7

Abstract

Severe vibration of the core of ultra-high voltage (UHV) shunt reactors under operating conditions often leads to the occurrence of suspension electrode, and such a suspended discharge defect will destroy the oil-paper insulation. It is necessary to investigate the influence of vibration on suspended discharge when determining the best operating condition of UHV shunt reactors. The vibration frequency of the suspension electrode and the phase difference between the applied voltage and the vibration are studied by simulation and experiment. The simulation results show that the phase difference between the voltage and the vibration parameters will lead to an increase in the surface maximum field strength. The distortion of the field intensity caused by several typical vibration frequencies of reactor vibration is ranked (in ascending order) thus: 100, 300, 50, and 200 Hz. There is a coupling relationship between the phase difference and the vibration frequency on the suspended discharge, which will lead to an inconsistency between the field intensity and each single factor. The partial discharge test results of the collision between the suspension electrode and the high-voltage electrode show that the discharge generated by vibration at 100 Hz is much higher than that at other frequencies, followed by those at 300 and 50 Hz, and the discharge generated by vibration at 200 Hz is very small. When the phase difference of voltage advance vibration is between 0° and 90°, the quantity of local discharge is large. When the phase difference is between 90° and 180°, the local discharge is small.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: High-Voltage Power Transmission Systems · High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Grid Shanxi Electric Power Company Electric Power Research Institute , 030001 Taiyuan, Shanxi, China

References (20)

Show source-provided references
1. Analysis on safe operation of national power grid in 2010
2. Calculation method of core vibration for UHV shunt reactor considering core lamellar rule and fluid-solid coupling10.13335/j.1000-3673.pst.2019.2503 ↗
3. Effect of air gap structure on core vibration of UHV shunt reactor10.16081/j.epae.202101016 ↗
4. Anisotropic magnetostriction of nonoriented silicon steel sheet and its frequency dependence10.1109/tmag.2015.2443133 ↗
5. Transformer fault diagnosis method based on vibration signal under fluctuating operating conditions10.13336/j.1003-6520.hve.20190910 ↗
6. Study on vibration characteristics of power transformer winding based on ‘magnetic-mechanical’ coupling field theory10.13334/j.0258-8013.pcsee.2016.09.030 ↗
7. Characteristic analysis of partial discharge of free metal particle in GIS10.1088/1755-1315/354/1/012121 ↗
8. Study on ultrasonic signal distribution characteristics of partial discharge caused by metal property defects in GIS10.13296/j.1001-1609.hva.2012.12.014 ↗
9. Bipolar DC corona discharge from a floating filamentary metal particle10.1109/28.980349 ↗
10. Diagnosis and analysis of partial discharge fault in a 220 kV transformer
11. Study on GIS partial discharge ultrasonic diagnosis method based on signal envelope spectrum10.13296/j.1001-1609.hva.2011.12.009 ↗
12. Analysis of decomposition products from suspension potential discharge inside SF6 circuit breaker10.13296/j.1001-1609.hva.2013.06.009 ↗
13. Suspension potential defect diagnosis of switchgear based on on-line detection technology
14. SF6 decomposition characteristics under suspension potential defects involving insulation materials10.13336/j.1003-6520.hve.20171227025 ↗
15. Abnormal signal diagnosis of GIS ultrasonic detection based on Hilbert-Yellow transform10.13296/j.1001-1609.hva.2019.06.003 ↗
16. Calculation and analysis of electric field discharge caused by suspension potential
17. Development and application of UHF sensor for GIS
18. The effect of a floating conductor on the breakdown strength of a DC gap at both polarities
19. Diagnosis and location method of transformer Partial discharge based on broadband acoustoelectric detection10.16527/j.issn.1003-6954.20220511 ↗
20. Bypass monitoring of partial discharge interference in ±800 kV converter transformer10.13336/j.1003-6520.hve.2015.03.022 ↗