journal article·2020-04-01Open access

Precision current measurement with thermal-drift-minimized offset current for single-parameter electron pumps based on gate-switching technique

Bum-Kyu Kim, Suk-In Park, Jindong Song, Hyung-Kook Choi, Wan-Seop Kim, Nam Kim, Myung-Ho Bae

AIP Advances· Volume 10· Issue 4

Abstract

Single-parameter single-electron pumps (SEPs) based on a quantum dot have been suggested as promising devices to realize the new definition of the unit of current, the ampere, where quantized current produced from the SEP device is only defined by the elementary charge e and applied external radiofrequency (rf), f, i.e., I = ef. The conventional method to eliminate offset signals in the precision current measurement of pump current has been to measure the current difference between the pump-on and pump-off states. To date, the rf-on and rf-off method has been used to pump between its on and off states. However, this method inevitably induces alternating rf-heating effects and varying temperatures of the device environment, possibly leading to a thermal drift of the offset current. In the current work, we developed a new gate-switching technique that can alternate the pump on and off states while maintaining a constant rf-on state, resulting in a more stable system temperature. Using the gate-switching technique, we achieved a temperature-stabilized environment and performed a precision current measurement with sub-parts per million uncertainty.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Quantum and electron transport phenomena · Advanced Electrical Measurement Techniques · Atomic and Subatomic Physics Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Korea Research Institute of Standards and Science 1 , Daejeon 34113, South Korea

Korea Institute of Science and Technology 2 , Seoul 02792, South Korea

Department of Physics, Research Institute of Physics and Chemistry, Jeonbuk National University 3 , Jeonju 54896, South Korea

Department of Nano Science, University of Science and Technology 4 , Daejeon 34113, South Korea

Funding

National Research Foundation of Korea · Korea Research Institute of Standards and Science · KIST

References (14)

Show source-provided references
1. Metrologia · 2018 · 55 · L1310.1088/1681-7575/aa950a ↗
2. Rep. Prog. Phys. · 2015 · 78 · 10390110.1088/0034-4885/78/10/103901 ↗
3. Rev. Mod. Phys. · 2013 · 85 · 142110.1103/revmodphys.85.1421 ↗
4. Nat. Commun. · 2012 · 3 · 93010.1038/ncomms1935 ↗
5. Metrologia · 2017 · 54 · S110.1088/1681-7575/54/1/s1 ↗
6. Appl. Phys. Lett. · 2016 · 109 · 01310110.1063/1.4953872 ↗
7. Nano Lett. · 2014 · 14 · 340510.1021/nl500927q ↗
8. Metrologia · 2015 · 52 · 19510.1088/0026-1394/52/2/195 ↗
9. Rev. Sci. Instrum. · 2015 · 86 · 02470310.1063/1.4907358 ↗
10. Rev. Sci. Instrum. · 2019 · 90 · 01470610.1063/1.5078572 ↗
11. 2012 · 706
12. Rev. Sci. Instrum. · 2017 · 88 · 02471110.1063/1.4975826 ↗
13. Metrologia · 2019 · 56 · 04400410.1088/1681-7575/ab29a5 ↗
14. Metrologia · 2020 · 57 · 02501310.1088/1681-7575/ab72e0 ↗