journal article·2023-01-01Open access

Design optimization of a truncated cone-shaped LaBr3:Ce/NaI:Tl phoswich detector based on GEANT4 simulation

R. P. Li, H. D. Wang, Jingbin Lu, Chengqian Li, Zirui Situ, Huan Qu

AIP Advances· Volume 13· Issue 1

Abstract

The anti-Compton phoswich (ACP) detector, which is composed of multiple scintillators with one photomultiplier tube, takes into account the Compton suppression function and portability, and therefore, a discussion on how to design its shape to improve the performance of the detector has become necessary. Based on an ACP detector using a well-typed LaBr3:Ce/NaI:Tl composite scintillator that has been developed in the laboratory in early work, this study uses GEANT4 to simulate and study the influence of the change in the shape and size of the secondary scintillator on the performance of the detector, such as the Compton suppression ratio, the energy resolution, and the full-energy peak (FEP) loss. In the course of the study, we mainly investigate the variation of the performance of the detector in two ways. First, the inclination angle of the truncated cone is gradually changed to compare its FEP address and Compton suppression ratio. Second, the case of the well-shaped and annular-shaped secondary scintillators is compared, respectively, to find out their impact on energy resolution and FEP address. The final results show that, compared with the ACP detector using a φ75 × 90 mm2 LaBr3:Ce/NaI:Tl cylindrical composite scintillator, a truncated cone-shaped composite scintillator of 0.8 inclination may have an equivalent 137% light yield (137% signal-to-noise ratio), a Compton suppression ratio of 89.62% (at 662 keV), 89.98% FWHM energy resolution, and a volume reduction of 36.74%, which means that the weight of the detector is reduced by 2.107 kg.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Radiation Detection and Scintillator Technologies · Medical Imaging Techniques and Applications · Atomic and Subatomic Physics Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Physics, Jilin University , Qianjin Street 2699, Changchun 130012, China

Funding

National Natural Science Foundation of China

References (20)

Show source-provided references
1. Radiation detection and measurement10.1109/PROC.1981.12016 ↗
2. Physics in nuclear medicine10.2967/jnumed.113.123125 ↗
3. S. Landsberger, F. Iskander, M. Niset, and K. Heydorn, “Compton suppression gamma ray spectrometry,” https://www.osti.gov/etdeweb/servlets/purl/20244475, 2002.
4. The correct and incorrect way to calibrate a Compton suppression counting system for gamma-ray efficiency10.1007/s10967-012-2123-1 ↗
5. Improvement of the Compton suppression ratio of a standard BGO suppressor system by a digital pulse shape analysis10.1016/j.nima.2007.06.058 ↗
6. Compton suppression systems for environmental radiological analysis10.1007/s10967-011-1362-x ↗
7. A digital Compton suppression spectroscopy without gamma-ray coincidence-summing loss using list-mode multispectral data acquisition10.1007/s10967-011-1588-7 ↗
8. A realistic solution of overcoming disadvantage of Compton suppression spectrometer10.1016/j.apradiso.2019.03.017 ↗
9. Multilayer phoswich scintillators for neutron/gamma discrimination10.1016/j.radmeas.2018.07.011 ↗
10. A well-type NaI(Tl)/BC404 phoswich detector for atmospheric radioxenon monitoring10.1016/j.nima.2020.164715 ↗
11. Digital pulse-shape discrimination of fast neutrons and γ rays10.1016/j.nima.2008.06.004 ↗
12. Energy resolution of LaBr3:Ce in a phoswich configuration with CsI:Na and NaI:Tl scintillator crystals10.1016/j.nima.2011.10.023 ↗
13. GEANT4—A simulation toolkit10.1016/S0168-9002(03)01368-8 ↗
14. Gamma backscattering analysis of flaw types and orientation based on Monte Carlo GEANT4 simulations10.1016/j.apradiso.2019.108924 ↗
15. Simulation of energy loss of fractionally charged particles using GEANT410.1016/j.nima.2020.164114 ↗
16. GEANT4 developments and applications10.1109/tns.2006.869826 ↗
17. Effects of ce concentration on scintillation properties of LaBr3:Ce10.1109/tns.2005.856906 ↗
18. Influence of the temperature dependence of the NaI(Tl) decay time constant on NaI(Tl) detector applications10.1109/tns.1977.4328663 ↗
19. A Compton suppression spectrometer for neutron activation analysis10.1016/0168-9002(95)01009-2 ↗
20. Accurate measurements of the rise and decay times of fast scintillators with solid state photon counters10.1088/1748-0221/7/09/p09004 ↗