journal article·2020-11-01Open access

The mathematical model of dissipation factor with temperature–frequency effect for oil-impregnated paper bushings

Quanmin Dai, Yanxia Liu, Guang Cheng

AIP Advances· Volume 10· Issue 11

Abstract

The accuracy of insulation defect diagnosis based on the dielectric spectrum response is severely influenced by temperature for oil-impregnated paper bushing. The dielectric loss (tan δ) mathematical model with a temperature–frequency factor to restrict the application of the frequency domain dielectric spectrum (FDS) for insulation diagnosis is not clear. In this paper, five temperatures are selected to study the frequency temperature characteristic of the FDS and polarization current for oil-impregnated paper bushing. The experimental results show that the temperature has different effects on the lower frequency (0.001 Hz–1 Hz) and higher frequency (1000 Hz–10 kHz) of FDS. With the increasing temperature, the lower frequency tan δ of 1 mHz–1 Hz shows a better pattern of exponential growth, while the higher frequency tan δ at 1 kHz–10 kHz shows the declining law with the rising temperature. With the increasing temperature, the polarization current shows a better pattern of exponential growth, while resistance obviously shows the declining law of the exponential pattern. The FDS curve of oil-impregnated paper bushings can be amended by the mathematical model of tan δ for the dielectric response on site for accuracy diagnosis.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation · Lightning and Electromagnetic Phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

College of Urban Rail Transit and Logistics, Beijing Union University , 100101 Beijing, China

Funding

R&D Program of Beijing Municipal Education commission · Premium Funding Project for Academic Human Resources Development in Beijing Union University · Beijing Municipal Natural Science Foundation

References (20)

Show source-provided references
1. On-line diagnostics of high-voltage bushings and current transformers using the sum current method10.1109/61.847244 ↗
2. On-line monitoring and diagnoses of power transformer bushings10.1109/tdei.2006.1657975 ↗
3. Estimation of water content in a power transformer using moisture dynamic measurement of its oil10.1049/hve.2016.0075 ↗
4. Transformer reliability survey
5. Deriving an equivalent circuit of transformers insulation for understanding the dielectric response measurements10.1109/tpwrd.2004.835436 ↗
6. Analysis of dielectric response measurements for condition assessment of oil-paper transformer insulation10.1109/tdei.2012.6396947 ↗
7. Dielectric response methods for diagnostics of power transformers10.1109/MEI.2003.1203017 ↗
8. On the frequency domain dielectric response of oil-paper insulation at low temperatures10.1109/tdei.2010.5492253 ↗
9. New diagnostic tools for high voltage bushings
10. Insulation condition diagnosis of oil-immersed paper insulation based on non-linear frequency-domain dielectric response10.1109/tdei.2018.007076 ↗
11. Quantitative analysis of insulation condition of oil-paper insulation based on frequency domain spectroscopy10.1109/tdei.2014.004490 ↗
12. Dielectric frequency response of oil-paper composite insulation with transient moisture distribution10.1109/TDEI.2013.6571459 ↗
13. Understanding the impact of moisture and ageing of transformer insulation on frequency domain spectroscopy10.1109/tdei.2014.6740761 ↗
14. Understanding and analysis on frequency dielectric parameter for quantitative diagnosis of moisture content in paper–oil insulation system10.1049/iet-epa.2014.0101 ↗
15. Influence of temperature on polarization and depolarization current of oil-paper insulation
16. Investigations of temperature effects on the dielectric response measurements of transformer oil-paper insulation system10.1109/tpwrd.2007.911123 ↗
17. Accurate temperature correction of dissipation factor data for oil-impregnated paper insulation bushings: Field experience
18. Dielectric frequency response measurements and dissipation factor temperature dependence
19. Moisture estimation for oil-immersed bushing based on FDS method: At a reference temperature10.1049/iet-gtd.2017.1591 ↗
20. Charge cluster triggers unpredictable insulation surface flashover in pressurized SF610.1088/1361-6463/abb38f ↗