Effects of parallel and meander configuration on thin-film magnetoimpedance element
Source abstract
Abstract
We investigated the effects of configuration of thin-film magnetoimpedance element on impedance profile. The parallel type and meander type sensor element were fabricated. The parallel line configuration has advantages to reduce a bias field and to enhance total inductance attributable to positive mutual inductance, while a large number of lines brings a decrement of impedance changes. The meander type induces a large demagnetizing effect and decrement of the total inductance due to negative mutual inductance. However, this configuration can utilize the space of the element, which contributes to enhance spatial resolution.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Metallic Glasses and Amorphous Alloys · Magnetic properties of thin films · Magnetic Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Science and Engineering, Iwate University , Morioka 020-8551, Japan
Funding
Japan Society for the Promotion of Science
References (23)
Show source-provided references
1. Appl. Phys. Lett. · 1994 · 65 · 118910.1063/1.112104 ↗
2. Nature · 1935 · 135 · 96110.1038/135961a0 ↗
3. IEEE Trans. Magn. · 1997 · 33 · 335310.1109/20.617943 ↗
4. Sens. Acta. A · 1997 · 59 · 2010.1016/s0924-4247(97)80143-4 ↗
5. Sens. Acta. A · 2003 · 106 · 18710.1016/s0924-4247(03)00164-x ↗
6. J. Appl. Phys. · 1996 · 79 · 655810.1063/1.361945 ↗
7. J. Appl. Phys. · 1998 · 84 · 280510.1063/1.368421 ↗
8. J. Appl. Phys. · 2000 · 88 · 37910.1063/1.373671 ↗
9. J. Magn. Magn. Mater. · 1999 · 195 · 76410.1016/s0304-8853(99)00286-3 ↗
10. IEEE Trans. Magn. · 2018 · 55 · 200040410.1109/tmag.2018.2868895 ↗
11. AIP Advances · 2018 · 8 · 05610210.1063/1.5004701 ↗
12. Adv. Mater. Lett. · 2019 · 10 · 30510.5185/amlett.2019.2202 ↗
13. J. Magn. Magn. Mater. · 2009 · 321 · 67510.1016/j.jmmm.2008.11.083 ↗
14. IEEE Trans. Magn. · 2012 · 48 · 383310.1109/tmag.2012.2198627 ↗
15. Biosens. Bioelectron. · 2014 · 58 · 33810.1016/j.bios.2014.03.008 ↗
16. Biosens. Bioelectron. · 2018 · 117 · 36610.1016/j.bios.2018.06.032 ↗
17. IEEE Trans. Magn. · 2005 · 41 · 369710.1109/tmag.2005.854812 ↗
18. IEEE Trans. Magn. · 2012 · 48 · 137510.1109/tmag.2011.2171330 ↗
19. J. Magn. Magn. Mater. · 2016 · 400 · 32110.1016/j.jmmm.2015.07.107 ↗
20. IEEE Magn. Lett. · 2016 · 7 · 650810510.1109/lmag.2016.2614795 ↗
21. J. Magn. Magn. Mater. · 2003 · 254–255 · 63610.1016/s0304-8853(02)00926-5 ↗
22. IEEE Trans. Magn. · 2008 · 44 · 225210.1109/tmag.2008.2001698 ↗
23. J. Magn. Magn. Mater. · 2010 · 322 · 283410.1016/j.jmmm.2010.04.038 ↗