journal article·2017-05-01Open access

Absolute-magnetic-field measurement using nanogranular in-gap magnetic sensor with second-harmonic and liquid-nitrogen-temperature operation

Keiji Tsukada, Takuya Yasugi, Yatsuse Majima, Kenji Sakai, Toshihiko Kiwa

AIP Advances· Volume 7· Issue 5

Abstract

To detect the absolute magnetic field, such as the earth’s magnetic field, a linear magnetic response, a zero point, and thermal stability are required. We thus propose an operating method and sensor probe consisting of a nanogranular in-gap magnetic sensor (GIGS), an operational amplifier integrated circuit, and a modulation coil. The sensor probe was operated in second-harmonic mode at a liquid-nitrogen (Liq. N2) temperature. When an AC magnetic field was applied to GIGS, the second-harmonic signal was generated and modulated by the outer magnetic field to be measured. After lock-in detection, the modulated output signal showed good linearity and a zero point. Moreover, higher sensitivity and low noise with low thermal fluctuation was obtained by the cooling at Liq. N2 temperature.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Magnetic Field Sensors Techniques · Magneto-Optical Properties and Applications · Characterization and Applications of Magnetic Nanoparticles

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Okayama University The Graduate School of Natural Science and Technology, , Okayama 700-8530, Japan

Funding

Japan Science and Technology Agency

References (25)

Show source-provided references
1. J. Appl. Phys. · 2015 · 117 · 17A32110.1063/1.4916036 ↗
2. Amer. Heart J. · 1963 · 66 · 9510.1016/0002-8703(63)90075-9 ↗
3. Science · 1967 · 156 · 65210.1126/science.156.3775.652 ↗
4. Rev. Sci. Instrum. · 1995 · 66 · 508510.1063/1.1146524 ↗
5. Sensors. · 2009 · 9 · 791910.3390/s91007919 ↗
6. IEEE Trans. Magn. · 1992 · 28 · 315010.1109/20.179741 ↗
7. Sens. Actuators A · 1997 · 59 · 110.1016/s0924-4247(97)80141-0 ↗
8. J. Am. Ceram. Soc. · 2008 · 91 · 35110.1111/j.1551-2916.2008.02259.x ↗
9. J Phys E: Sci. Instrum. · 1979 · 12 · 24110.1088/0022-3735/12/4/001 ↗
10. Sens. Actuators A · 1992 · 33 · 12910.1016/0924-4247(92)80159-z ↗
11. 2004
12. Physica C · 2008 · 468 · 193610.1016/j.physc.2008.05.171 ↗
13. Meas. Sci. Technol. · 1995 · 6 · 89810.1088/0957-0233/6/7/007 ↗
14. Sens. Actuators A · 1999 · 76 · 22510.1016/s0924-4247(99)00034-5 ↗
15. IEEE Trans. Magn. · 2011 · 47 · 353810.1109/tmag.2011.2148113 ↗
16. J. Appl. Phys. · 2001 · 90 · 415910.1063/1.1376415 ↗
17. J. Magn. Magn. Mater. · 1999 · 179 · 198
18. J. Magn. Magn. Mater. · 2007 · 310 · 250310.1016/j.jmmm.2006.11.095 ↗
19. J. Low Temp. Phys. · 1977 · 27 · 301
20. Appl Phys. Lett. · 2015 · 106 · 05240410.1063/1.4907621 ↗
21. J. Appl. Phys. · 2005 · 97 · 10Q10710.1063/1.1861375 ↗
22. IEEE. Trans. Mag. · 1982 · 18 · 70710.1109/tmag.1982.1061834 ↗
23. Phy. Rev. B · 1989 · 39 · 699510.1103/physrevb.39.6995 ↗
24. Phys. Rev. Lett. · 1976 · 37 · 142910.1103/physrevlett.37.1429 ↗
25. Phys. Rev. Lett. · 1973 · 31 · 4410.1103/physrevlett.31.44 ↗