Fault section identification using zero-sequence current carrier signaling in ungrounded power distribution systems
Source abstract
Abstract
In isolated-neutral distribution networks, single-phase-to-earth faults generate extremely weak fault currents with complex spatial distributions, rendering conventional manual patrols inefficient and expensive. This paper derives closed-form expressions for the magnitude and phase of zero-sequence currents along feeders with radial and tree topologies, establishing segment-level criteria based on magnitude discontinuities and phase reversals. Building on these analytical results, a distributed zero-sequence current carrier-monitoring scheme is proposed: each zero-sequence current transformer is assigned a unique high-frequency carrier, mapping geographical position to a frequency signature, thereby enabling fault-section identification without additional communication infrastructure. The effectiveness of the proposed method is verified through comprehensive simulations.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Power Systems Fault Detection · Electrical Fault Detection and Protection · Islanding Detection in Power Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Wuhan Institute of Shipbuilding Technology 1 , Tieqiao South Village, Qingchuan Street, Hanyang District, Wuhan City, Hubei Province 430050,
Boertala Polytechnic 2 , Sai Limu Lake Road, Bole City, Bortala Mongol Autonomous Prefecture, Xinjiang Uyghur Autonomous Region 833400,
Funding
Guiding Project of the Scientific Research Plan of the Hubei Provincial Education Department
References (12)
Show source-provided references
1. Segment location for single-phase-to-ground fault in neutral non-effectively grounded system based on distributed electric-field measurement10.1016/j.epsr.2020.106321 ↗
2. Resilience enhancement of active distribution networks under extreme disaster scenarios: A comprehensive overview of fault location strategies10.1016/j.rser.2023.113898 ↗
3. Research on cable fault detection and localization method using impedance spectroscopy
4. Oscillatory localization and impedance-coordinated method for multi-converter power systems based on the impedance network matrix10.1016/j.ijepes.2025.110560 ↗
5. An improved traveling-wave-based fault location method with compensating the dispersion effect of traveling wave in wavelet domain10.1155/2017/1019591 ↗
6. Computational fault time difference-based fault location method for branched power distribution networks10.1109/access.2019.2959427 ↗
7. Fault detection and classification in ring power system with DG penetration using hybrid CNN-LSTM10.1109/access.2024.3394166 ↗
8. High impedance fault detection in distribution systems: An approach based on Fourier transform and artificial neural networks
9. High impedance fault detection using advanced distortion detection technique10.1109/TPWRD.2020.2973829 ↗
10. A high-impedance fault detection method for active distribution networks based on time–frequency–space domain fusion features and hybrid convolutional neural network10.3390/pr12122712 ↗
11. Distribution network voltage arc suppression method based on flexible regulation of neutral point potential of the new grounding transformer10.3389/fenrg.2022.803142 ↗
12. Advances on fault detection techniques for resonant grounded power distribution networks in bushfire prone areas: Identification of faulty feeders, faulty phases, faulty sections, and fault locations10.1016/j.epsr.2023.109265 ↗