Uncertainty quantification of Abel inversion in multi-energy x-ray radiography with spatially varying noise
Source abstract
Abstract
Abel inversion is a classical technique for reconstructing the volumetric density of axisymmetric objects from line-integral projections in x-ray radiography. However, traditional methods often rely on simplifying assumptions such as monochromatic x-ray sources and homoscedastic Gaussian noise, which do not hold in practical experiments such as micron-ejecta studies. This paper presents a hierarchical Bayesian framework with Markov Chain Monte Carlo sampling for uncertainty quantification in Abel inversion under more realistic conditions, including polychromatic x-ray spectra and spatially varying noise. We introduce a “step wedge method” to calibrate the energy spectrum and noise characteristics and propose a modified prior structure to improve reconstruction accuracy near the symmetry axis. The method is validated on both synthetic and real experimental data from a 4 MeV pulsed x-ray radiography system. Results demonstrate accurate density reconstruction with explicit uncertainty bounds, highlighting the method’s robustness and applicability in dynamic imaging diagnostics.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced X-ray and CT Imaging · Medical Imaging Techniques and Applications · Advanced X-ray Imaging Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
National Key Laboratory of Shock Wave and Detonation Physics, Institute of Fluid Physics, CAEP , P.O. Box 919-105, Mianyang, Sichuan 621900,
Funding
National Key Laboratory of Shockwave and Detonation Physics · The Presidential foundation of CAEP
References (23)
Show source-provided references
1. Poularikas · 201810.1201/9781315218915 ↗
2. Analytic and numerical methods for the Abel transform of exponential functions for planetary and cometary atmospheres10.1016/j.icarus.2021.114654 ↗
3. Is there substructure around M87?10.1093/mnras/stw1574 ↗
4. Improving the Abel transform inversion using bending angles from FORMOSAT-3/COSMIC10.1007/s10291-009-0147-y ↗
5. Application of the Abel inversion in case of a tensor field10.1080/17415970903545124 ↗
6. Diagnostic of laser-induced plasma using Abel inversion and radiation modeling10.1366/12-06929 ↗
7. Proton radiography measurements and models of ejecta structure in shocked Sn10.1063/1.5044848 ↗
8. 1977
9. Nonlinear total variation based noise removal algorithms10.1016/0167-2789(92)90242-f ↗
10. 1996
11. Abel inversion using total-variation regularization10.1088/0266-5611/21/6/006 ↗
12. MCMC-based image reconstruction with uncertainty quantification10.1137/11085760x ↗
13. Bayesian Abel inversion in quantitative x-ray radiography10.1137/15m1018721 ↗
14. Uncertainty quantification of density reconstruction using MCMC method in high-energy x-ray radiography10.4208/cicp.oa-2019-0060 ↗
15. Effects of shock-breakout pressure on ejection of micron-scale material from shocked tin surfaces10.1063/1.2752130 ↗
16. A stochastic approach to quantifying the blur with uncertainty estimation for high-energy x-ray imaging systems10.1080/17415977.2015.1046859 ↗
17. Forward model with space-variant of source size for reconstruction on x-ray radiographic image10.1016/j.nima.2017.11.056 ↗
18. Decreasing the scatter effect in density reconstruction in high-energy x-ray radiography10.1016/j.nima.2013.03.050 ↗
19. J. F. Briesmeister , “MCNPTM-A general Monte Carlo N-particle transport code,” Version 4C, LA-13709-M, Los Alamos National Laboratory 2, 2000.
20. Hypermodels in the Bayesian imaging framework10.1088/0266-5611/24/3/034013 ↗
21. A Gaussian hypermodel to recover blocky objects10.1088/0266-5611/23/2/016 ↗
22. A primer on space-time modeling from a Bayesian perspective10.1201/9781420011050.ch6 ↗
23. 2013