Concentration calculation model for calibration of non-dispersive infrared gas detection system
Source abstract
Abstract
Non-dispersive infrared (NDIR) gas detection systems have been extensively used for gas monitoring because they are considered the simplest approach with moderate sensitivity and fast response. Concentration calculation models for calibration are particularly important in NDIR gas detection systems because of the nonlinear relationship between the output voltage ratio and concentration. We propose a concentration calculation model with two fitting parameters for non-dispersive infrared gas detection systems, accounting for the fact that not all IR radiation that impinges upon the detector is absorbed by the gas and for the saturation effects in absorption peaks leading to the nonlinear relationship. Despite the small number of fitting parameters of the proposed concentration calculation model, it presents high quality curve fitting to experimental data. The performance of the proposed model is compared to that of other concentration calculation models.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Spectroscopy and Laser Applications · Atmospheric Ozone and Climate · Calibration and Measurement Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Department of Physics, Kim Il Sung University , Taesong District, Pyongyang,
References (26)
Show source-provided references
1. Towards integrated mid-infrared gas sensors10.3390/s19092076 ↗
2. The HITRAN2016 molecular spectroscopic database10.1016/j.jqsrt.2017.06.038 ↗
3. 1996
4. Infrared spectroscopy of proteins10.1016/j.bbabio.2007.06.004 ↗
5. Mid-infrared frequency combs10.1038/nphoton.2012.142 ↗
6. From 1D to 2D to 3D: Electrospun microstructures towards wearable sensing10.3390/chemosensors11050295 ↗
7. Integrated, selective, simultaneous multigas sensing based on nondispersive infrared spectroscopy-type photoacoustic spectroscopy10.1021/acssensors.3c01285 ↗
8. 2008
9. Non-dispersive infra-red (NDIR) measurement of carbon dioxide at 4.2 μm in a compact and optically efficient sensor10.1016/j.snb.2013.06.006 ↗
10. A low cost MEMS based NDIR system for the monitoring of carbon dioxide in breath analysis at ppm levels10.1016/j.snb.2016.04.016 ↗
11. Development of a lowcost NDIR system for ppm detection of carbon dioxide in exhaled breath analysis10.1016/j.proeng.2015.08.648 ↗
12. NDIR gas sensor for spatial monitoring of carbon dioxide concentrations in naturally ventilated livestock buildings10.3390/s150511239 ↗
13. Non-dispersive infrared gas sensing technology: A review10.1109/jsen.2021.3130034 ↗
14. Multiplex-gas detection based on non-dispersive infrared technique: A review10.1016/j.sna.2023.114318 ↗
15. A novel solid state non-dispersive infrared CO2 gas sensor compatible with wireless and portable deployment10.3390/s130607079 ↗
16. Enhancing methane sensing with NDIR technology: Current trends and future prospects10.1515/revac-2023-0062 ↗
17. Optical gas sensing: A review10.1088/0957-0233/24/1/012004 ↗
18. Multi-gas detection system based on non-dispersive infrared (NDIR) spectral technology10.3390/s22030836 ↗
19. A NDIR mid-infrared methane sensor with a compact pentahedron gas-cell10.3390/s20195461 ↗
20. Complete gas sensor circuit using nondispersive infrared (NDIR)
21. 2007 · 1
22. 2024 · 1
23. 2009 · 1
24. 2009 · 1
25. Non-dispersive infrared multi-gas sensing via nanoantenna integrated narrowband detectors10.1038/s41467-020-19085-1 ↗
26. Mean absorption and equivalent absorption coefficient of a band spectrum10.1103/physrev.54.126 ↗