journal article·2025-02-01Open access

Research on dynamic ablative behavior of contact during breaking of DC circuit breaker

Ze Guo, Chuanjun Ma, Zixu Guo, Hang Liu, Xiangji Chen

AIP Advances· Volume 15· Issue 2

Abstract

During the circuit breaker’s breaking process, an arc is generated, which exerts an ablative effect on the contacts and significantly impacts the electrical life of the circuit breaker. Therefore, studying the ablation mechanism of arcs is crucial for enhancing the breaking performance and extending the electrical life of circuit breakers. To investigate the ablation effect of arcs on contacts, a double-break DC circuit breaker model was developed. Utilizing magnetohydrodynamics theory, FLUENT software was employed to simulate the arc motion, establish the energy balance equation for arcing and contacts, analyze the ablation mechanism during arc ignition, and calculate the mass loss of contacts during a single arc event. An experimental platform was established to conduct electrical life tests on the circuit breaker. The ablation mass loss was measured through these tests. The results indicate that under identical breaking conditions, the experimental outcomes align with the simulation results. Building on this, the influence of the breaker’s breaking speed on contact ablation was examined. Simulation results reveal that the arc ablation at the end of the contact is most severe during the combustion process, and as the breaking speed increases, the extent of arc ablation on the contact gradually diminishes.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Vacuum and Plasma Arcs · Electrical Fault Detection and Protection · High voltage insulation and dielectric phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

State Key Laboratory of Reliability and Intelligence of Electrical Equipment, Hebei University of Technology 1 , Tianjin 300130,

Key Laboratory of Electromagnetic Field and Electrical Apparatus Reliability of Hebei Province, Hebei University of Technology 2 , Tianjin 300130,

References (28)

Show source-provided references
1. Arc simulation and performance optimization of non-polar low voltage DC circuit breaker based on magnetohydrodynamics10.16628/j.cnki.2095-8188.2024.02.002 ↗
2. Review on structure innovation and intelligent control technology of AC contactor10.16628/j.cnki.2095-8188.2021.02.001 ↗
3. Residual life prediction of AC contactor based on LSTM10.13336/j.1003-6520.hve.20220082 ↗
4. Research on motion analysis and fault diagnosis of contact system of AC contactor10.19595/j.cnki.1000-6753.tces.L90315 ↗
5. Review on arc mechanism and arc extinguishing technology of multi-electric aircraft circuit Breakers10.13374/j.issn2095-9389.2022.02.28.002 ↗
6. Review of low voltage DC arc detection and breaking technology10.16628/j.cnki.2095-8188.2024.08.001 ↗
7. Study on electric life distribution characteristics of AC contactors based on contact arc erosion10.13334/j.0258-8013.pcsee.162430 ↗
8. Simulation of auto-expansion high voltage SF6 circuit breaker breaking process considering valve motion10.1063/5.0222063 ↗
9. Research review on contact ablation and electrical life evaluation of high voltage circuit breakers10.13336/j.1003-6520.hve.20230862 ↗
10. Electric life prediction method of DC circuit breakers based on residual network regression10.16628/j.cnki.2095-8188.2024.10.002 ↗
11. Review on mathematical model and characteristics of air switching arc
12. A comparison of the effects of different mixture plasma properties on arc motion10.1088/0022-3727/40/22/019 ↗
13. Magnetohydrodynamic modeling and characteristic simulation of air switching arc10.13334/j.0258-8013.pcsee.2007.21.008 ↗
14. Numerical analysis of arc plasma behaviour during contact opening process in low-voltage switching device10.1088/0022-3727/40/3/016 ↗
15. Numerical analysis of the influence of splitter-plate erosion on an air arc in the quenching chamber of a low-voltage circuit breaker10.1088/0022-3727/43/43/434011 ↗
16. Numerical simulation and analysis of high current air arc gate blade ablation10.13336/j.1003-6520.hve.20231601 ↗
17. Simulation study on ablative characteristics of contact under arc
18. Vacuum arc cathode spots ablation morphology experiment and modeling simulation research review10.16540/j.cnki.cn11-2485/tn.2023.05.01 ↗
19. Experimental study on effect of frequency on air arc ignition characteristics of low voltage circuit breaker10.13336/j.1003-6520.hve.20201179 ↗
20. Effect of short circuit current on valve motion characteristics during arc breaking of SF6 circuit breaker with self-energy expansion10.13336/j.1003-6520.hve.2015.09.048 ↗
21. Simulation study on arc motion process of 38 A low-voltage AC contactor under AC-4 conditions10.1063/5.0191678 ↗
22. Arc simulation of high voltage DC molded case circuit breaker
23. Simulation of longitudinal magnetic field of vacuum interrupter at high frequency10.13296/j.1001-1609.hva.2020.11.026 ↗
24. Study on effect of longitudinal magnetic field on microscopic characteristics of vacuum arc10.13296/j.1001-1609.hva.2019.07.010 ↗
25. 2018
26. Ablation characteristics of contact under DC air arc10.13336/j.1003-6520.hve.20200615015 ↗
27. Research review on the ablation of electrodes by air arc10.16628/j.cnki.2095-8188.2017.07.001 ↗
28. Modeling and simulation study on the ablation characteristics of DC contactor contact10.1063/5.0174290 ↗