Ultrasonic propagation characteristics of partial discharge in oil-impregnated paper traction transformer
Source abstract
Abstract
Partial Discharges (PDs) are a significant factor in reducing the insulation life of traction transformers. In recent years, the Acoustic Emission (AE) method has become the most advanced method for detecting PD signals in transformers. The AE method utilizes AE sensors placed on the transformer tank to detect ultrasonic signals emitted by PD and determine the Time Of Arrival (TOA) of the head wave. The windings and cores of a traction transformer consist mainly of metal, which greatly affects the propagation of PD ultrasonic waves. This paper establishes a 110 kV “pressure acoustic, transient” physical field model of the traction transformer with dimensions of 4.63 × 1.48 × 2.84 m3. The model is used to carry out the PD pressure acoustic physical field simulation study of the traction transformer, to clarify the physical characteristics of the ultrasound of the PD defects, and to establish observation points on the transformer tanks to receive ultrasonic time-domain waveforms for PD detection. The simulation results indicate that PD ultrasonic waves exhibit complex propagation characteristics, including reflection, refraction, and reverberation, as they pass through the windings and cores to the observation points. The TOA of the head wave in the ultrasound time-domain waveform is indicated by the first maximum value of the wave crest line. Finally, this paper proposes a multi-level localization method based on the AE method to determine which winding generates the PD in the large-scale traction transformer using only four dynamically moving observation points.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Power Transformer Diagnostics and Insulation · Aerosol Filtration and Electrostatic Precipitation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Urban Rail Transit and Logistics, Beijing Union University 1 , Beijing 100101, China
Baoding Railway Transformer Branch, China Railway Electric Co., Ltd. 2 , Baoding 071051, China
Funding
Beijing Municipal Education Commission · Beijing Union University · Scientific Research Project of China Railway Electrification Engineering Group
References (18)
Show source-provided references
1. Influences of traction load shock on artificial partial discharge faults within traction transformer—Experimental test for pattern recognition10.3390/en10101556 ↗
2. Calculation of a relative actualized transformer power of a traction substation on insulation aging10.3103/s1068371211080025 ↗
3. A systematic approach to hybrid railway power conditioner design with harmonic compensation for high-speed railway10.1109/tie.2014.2341577 ↗
4. A novel active power quality compensator topology for electrified railway10.1109/tpel.2004.830032 ↗
5. Thermal overshoot analysis for hot-spot temperature rise of transformer10.1109/tdei.2007.4339495 ↗
6. Investigation of partial discharges within power oil transformers by acoustic emission10.3390/en16093779 ↗
7. Acoustic localization of partial discharge sources in power transformers using a particle-swarm-optimization-route-searching algorithm10.1109/tdei.2017.006857 ↗
8. Survey of finite element method-based real-time simulations10.3390/app9142775 ↗
9. Partial discharge localization inside transformer windings via fiber-optic acoustic sensor array10.1109/tpwrd.2018.2880230 ↗
10. Iterative method for partial discharges location in power transformers10.1016/j.epsr.2022.108225 ↗
11. Performance analysis of acoustic sensors based time reversal technique for partial discharge localization in power transformers10.1016/j.epsr.2022.108965 ↗
12. Modelling of acoustic wave propagation due to partial discharge and its detection and localization in an oil-filled distribution transformer10.1515/freq-2019-0050 ↗
13. Investigation on the effect of underwater acoustic pressure on the fundamental mode of hollow-core photonic bandgap fibers10.1155/2015/815967 ↗
14. Acoustic based localization of partial discharge inside oil-filled transformers10.1109/access.2022.3177603 ↗
15. Running status diagnosis of onboard traction transformers based on kernel principal component analysis and fuzzy clustering10.1109/access.2021.3108345 ↗
16. A maximum-likelihood TDOA localization algorithm using difference-of-convex programming10.1109/lsp.2021.3051836 ↗
17. Range-extension algorithms and strategies for TDOA ultra-wideband positioning system10.3390/s23063088 ↗
18. Localizing multiple sound sources using an array of autonomous, asynchronous receivers10.1121/10.0023329 ↗