An improved measurement scheme of the large-caliber steady-state magnetic-field testing system for ITER
Source abstract
Abstract
The large-caliber steady-state magnetic-field testing system is an important device for the International Thermonuclear Experimental Reactor, which is mainly used for electromagnetic compatibility tests in a strong magnetic field environment. The uniform magnetic field area needs to be measured to ensure the correctness of the design after the completion of the platform. This paper mainly analyzes the relationship between the magnetic field probe and error, studies the detection effect of different arrangement methods of magnetic field probe points, and obtains a more accurate probe arrangement method through comparative analysis. Then, the principle and structure of the acquisition and detection system are studied, and the multipoint synchronous Hall array magnetic field detection system of the magnetic field is built by using the Hall probe to realize the omnidirectional measurement of the magnetic field. Finally, the Hall probe is calibrated and tested by experiments, and a test platform is built to test the magnetic field. The results verify the correctness of the analysis.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magnetic Field Sensors Techniques · Magnetic confinement fusion research · Atomic and Subatomic Physics Research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Institute of Plasma Physics, Hefei Institutes of Physical Science, Chinese Academy of Sciences 1 , Hefei 230031, China
University of Science and Technology of China 2 , Hefei 230026, China
Funding
National Key Research and Development Plan · Comprehensive Research Facility for Fusion Technology
References (18)
Show source-provided references
1. ITER: The first experimental fusion reactor10.1016/0920-3796(95)90113-2 ↗
2. Status of ITER10.1016/S0920-3796(02)00218-1 ↗
3. Static and transient magnetic field maps at level B1 tokamak complex
4. Assessment of magnetic field and its maximum time derivative in Tokamak building
5. Magnetic compatibility of standard components for electrical installations: Tests on programmable logical controllers and other electronic devices10.1016/j.fusengdes.2005.06.278 ↗
6. Magnetic compatibility of standard components for electrical installations: Computation of the background field and consequences on the design of the electrical distribution boards and control boards for the ITER Tokamak building10.1016/j.fusengdes.2005.06.136 ↗
7. Magnetic compatibility of standard components for electrical installations: Tests on low voltage circuit breakers and contactors10.1016/j.fusengdes.2005.06.267 ↗
8. Test method for ITER equipment for static (d.c.) magnetic fields
9. Study and analysis of magnetic field homogeneity of square and circular Helmholtz coil pairs: A Taylor series approximation
10. Design of highly uniform magnetic field coils based on a particle swarm optimization algorithm10.1109/ACCESS.2019.2933608 ↗
11. Design of highly uniform magnetic field coils with wolf pack algorithm10.1109/jsen.2020.3030622 ↗
12. Research on the design method of uniform magnetic field coil based on the MSR10.1109/tie.2019.2899544 ↗
13. Design of highly uniform three dimensional spherical magnetic field coils for atomic sensors10.1109/jsen.2020.2997800 ↗
14. Effects of the winding cross section shape on the magnetic field uniformity of the high field circular Helmholtz coil systems10.1109/tie.2017.2686302 ↗
15. An improved two-coil configuration for low-frequency magnetic field immunity tests and its field inhomogeneity analysis10.1109/tie.2018.2807420 ↗
16. Optimal design method to improve the magnetic field distribution of multiple square coil systems10.1109/access.2020.3024653 ↗
17. Design and error analysis of a large-caliber steady-state magnetic-field testing system10.1109/tmag.2019.2958567 ↗
18. Temperature field calculation and water cooling design of the magnetic field immunity testing system10.1016/j.fusengdes.2021.112515 ↗