Determining carrier frequency for implantable human body communication based on transmission efficiency–electromagnetic interference trade-off
Source abstract
Abstract
This study proposes a novel methodology for determining the optimal carrier frequency for implantable human body communication (HBC) by focusing on the trade-off between transmission efficiency and electromagnetic interference (EMI) robustness. Traditional radio communication technologies use high-frequency bands, which pose some challenges, such as increased power consumption, EMI with other devices, and security risks. Implantable HBC is a promising alternative, wherein the human body is used as a transmission medium. Through phantom experiments simulating the human abdomen, we assess the transmission characteristics of implantable HBC between an abdominal neurostimulator and an external controller across a frequency range of 1–100 MHz. Results revealed that maximum transmission gain was achieved at 37.2 MHz. Moreover, rapid signal attenuation occurred beyond a minimal distance from the skin, indicating enhanced communication efficiency, reduced EMI, and enhanced information security. An evaluation index (EI) was also proposed to quantitatively assess the balance between transmission efficiency and EMI and determine an appropriate carrier frequency for specific implantable HBC applications. This study advances the field of implantable medical devices by optimizing communication performance while addressing key challenges in EMI and security.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Wireless Body Area Networks · Molecular Communication and Nanonetworks · Energy Harvesting in Wireless Networks
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
The University of Electro-Communications 1-5-1 Chofugaoka , Chofu, Tokyo 182-8585, Japan
Funding
Japan Society for the Promotion of Science · KDDI Foundation
References (41)
Show source-provided references
1. An ultra-miniaturized antenna with ultra-wide bandwidth for future cardiac leadless pacemaker10.1109/tap.2022.3161513 ↗
2. 2021 · 1
3. Development of a high-speed implant communication module deep into the human body: Realized in the 10–60-MHz band with small antennas [bioelectromagnetics]10.1109/map.2022.3162808 ↗
4. Galvanic impulse wireless communication for biomedical implants10.1109/access.2021.3064206 ↗
5. B. V. Medtronic , PillCamTM Capsule Endoscopy User Manual, 2016.
6. Confirm Rx insertable cardiac monitor for primary atrial fibrillation detection in high-risk heart failure patients (confirm-AF trial)10.1111/anec.13021 ↗
7. Wireless powering and telemetry of deep-body ingestible bioelectronic capsule10.1109/tap.2022.3184549 ↗
8. Compact triple-band implantable antenna for multitasking medical devices10.2478/jee-2022-0022 ↗
9. EM interaction of handset antennas and a human in personal communications10.1109/5.362755 ↗
10. 2005 · 7754
11. Modeling and characterization of biotelemetric radio channel from ingested implants considering organ contents10.1109/tap.2009.2014531 ↗
12. The attenuation characteristics of the body tissue on frequency function in WBAN channel10.12962/jaree.v5i2.185 ↗
13. Propagation-loss characterization for livestock implantables at (433, 868, 1400) MHz10.1109/tap.2021.3060501 ↗
14. Bluetooth signal attenuation analysis in human body tissue analogues10.1109/access.2021.3087780 ↗
15. American National Standards Institute, “American National Standard recommended practice for an on-site, ad hoc test method for estimating electromagnetic immunity of medical devices to radiated radio-frequency (RF) emissions from RF transmitters,” in ANSI C63.18-2014 (Revision of ANSI C63.18-1997) (2014), pp. 1–64.
16. Testing the immunity of active implantable medical devices to CW magnetic fields up to 1 MHz by an immersion method10.1109/tbme.2007.893502 ↗
17. 2011 · 101
18. 2018 · 1
19. Emerging electromagnetic interferences between implantable cardioverter-defibrillators and left ventricular assist devices10.1093/europace/euaa006 ↗
20. 2022 · 124
21. A survey on security issues in modern Implantable Devices: Solutions and future issues10.1016/j.smhl.2022.100295 ↗
22. 2020 · 1
23. 2020 · 0488
24. Cybersecurity: The need for data and patient safety with cardiac implantable electronic devices10.1016/j.hrthm.2020.10.009 ↗
25. Review of security challenges in healthcare internet of things10.1007/s11276-020-02340-0 ↗
26. Signal transmission analysis in implantable human body communication for abdominal medical devices10.1063/5.0157485 ↗
27. Enabling covert body area network using electro-quasistatic human body communication10.1038/s41598-018-38303-x ↗
28. 2020
29. IEEE Standards Association, IEEE Standard for Local and metropolitan area networks—Part 15.6: Wireless Body Area Networks, 2012.
30. Transmission analysis in human body communication for head-mounted wearable devices10.3390/electronics10101213 ↗
31. Review of medical implant communication system (MICS) band and network10.1016/j.icte.2016.08.010 ↗
32. 2021 · 1
33. The thickness of the skin10.1097/00006534-195505000-00006 ↗
34. Phys. Med. Biol. · 1996 · 41 · 225110.1088/0031-9155/41/11/002 ↗
35. Development and study of electrical property on phantom for human body communication considering tissue structure of human arm10.5104/jiep.17.63 ↗
36. St. Jude Medical, Proclaim Implantable Pulse Generator Clinician’s Manual, 2017.
37. In-body to on-body ultrawideband propagation model derived from measurements in living animals10.1109/jbhi.2015.2417805 ↗
38. Channel characteristics and wireless telemetry performance of transplanted organ monitoring system using ultrawideband communication10.1109/jerm.2018.2827779 ↗
39. Tissue-dependent Co-matching method for dual-mode antenna in implantable neurostimulators10.1109/tap.2019.2916736 ↗
40. 2019 · 1
41. A quantitative analysis of physical security and path loss with frequency for IBOB channel10.1109/lmwc.2022.3163077 ↗