Abstract

We investigated the magnetization response and heat generation of magnetic particles exposed to high-speed pulsed magnetic fields (PMF) during magnetic hyperthermia cancer treatment. The magnetization measurements exhibited an asymmetric change in the shape of the hysteresis loop, attributable to the rapid and substantial changes in the short-duration PMF (75 mT/μs). We propose a novel parameter to evaluate heat efficiency. The parameter considered disparities in waveforms and served as a valuable metric for evaluating the effectiveness of heat production. Our findings affirmed a substantial enhancement in heat efficiency with the application of PMF. Furthermore, the heat generation stemming from the magnetic energy dissipation within the PMF exhibited direct proportionality to the square of the field amplitude. The heat efficiency is fourfold higher than that generated by conventional waveform.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Advanced MRI Techniques and Applications · NMR spectroscopy and applications

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Graduate School of Engineering, Tohoku University 1 , Miyagi 980-0865, Japan

High Energy Accelerator Research Organization (KEK) 2 , Tsukuba 305-0801, Japan

Department of Biomedical Engineering, Tohoku University 3 , Miyagi 980-8579, Japan

Funding

Japan Agency for Medical Research and Development · KAKENHI · the Comprehensive Growth Program for Accelerator Science and the Joint Development Research · Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering

References (19)

Show source-provided references
1. Biologically targeted magnetic hyperthermia: Potential and limitations10.3389/fphar.2018.00831 ↗
2. Heating characteristics of RF capacitive-type heating device10.3191/thermalmed.36.59 ↗
3. Heating technology for malignant tumors10.1080/02656736.2020.1779357.Heating ↗
4. Magnetic hyperthermia therapy for the treatment of glioblastoma: A review of the therapy’s history, efficacy and application in humans10.1080/02656736.2018.1430867 ↗
5. Enhanced specific loss power from Resovist® achieved by aligning magnetic easy axes of nanoparticles for hyperthermia10.1016/j.jmmm.2018.10.070 ↗
6. Optimization of resonant circuit and evaluation of magnetic field uniformity with 50 mm gap magnetic field generator10.3379/msjmag.1805r005 ↗
7. Animal experiment with PID-based automatic temperature control system for magnetic hyperthermia
8. Thermoradiotherapy of deep-seated tumors: Analysis of Joint research at several institutions10.3191/thermalmedicine.6.411 ↗
9. Carbothermal treated iron oxide nanoparticles with improving magnetic heating efficiency for hyperthermia10.1016/j.rinp.2021.105095 ↗
10. Synopsis of IEEE std C95.1TM-2019 ‘IEEE standard for safety levels with respect to human exposure to electric, magnetic, and electromagnetic fields, 0 Hz to 300 GHz10.1109/ACCESS.2019.2954823 ↗
11. Magnetic particle hyperthermia-biophysical limitations of a visionary tumour therapy10.1016/j.jmmm.2006.10.1156 ↗
12. Configurable high-frequency alternating magnetic field generator for nanomedical magnetic hyperthermia applications10.1109/ACCESS.2021.3099428 ↗
13. Enhancing magnetic hyperthermia nanoparticle heating efficiency with non-sinusoidal alternating magnetic field waveforms10.3390/nano11123240 ↗
14. Ultra-short pulse magnetic fields on effective magnetic hyperthermia for cancer therapy10.1063/9.0000558 ↗
15. Heating of magnetic particles by application of high frequency pulsed magnetic field
16. Effect of applied magnetic field on permeability and heating efficiency of multifunctional micro/nano-magnetic particles for hyperthermia therapy10.1063/9.0000123 ↗
17. Exploring the potential of the dynamic hysteresis loops via high field, high frequency and temperature adjustable AC magnetometer for magnetic hyperthermia characterization10.1080/02656736.2020.1802071 ↗
18. Suitability of commercial colloids for magnetic hyperthermia10.1016/j.jmmm.2009.02.075 ↗
19. Heating magnetic fluid with alternating magnetic field10.1016/s0304-8853(02)00706-0 ↗