journal article·2023-02-01Open access

Rapid virus detection using magnetic second harmonics of superparamagnetic iron oxide nanoparticles

Ryuichi Hirota, Toru Murayama, Ryota Katsumi, Tokuhisa Kawawaki, Shin Yabukami, Ryuji Igarashi, Yuichi Negishi, Moriaki Kusakabe, Masaki Sekino, Takashi Yatsui, Akihiro Kuwahata

AIP Advances· Volume 13· Issue 2

Abstract

Virus detection methods based on nonlinear magnetic response of magnetic nanoparticles have been investigated, and magnetic detection methods using the third harmonic are widely applied, owing to their high sensitivity and short measurement time. This paper proposes a virus detection method based on the second harmonic because of its larger signal component. We found that the second harmonic signal is superior to the third harmonic signal for small nanobeads and a large change of the second harmonic signal in the signal-to-noise ratio (SNR) with nanobeads concentration. In addition, a virus detection limit of 100 pg/ml is achieved. Therefore, the proposed method can potentially be utilized for rapid screening of viruses.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Characterization and Applications of Magnetic Nanoparticles · Biosensors and Analytical Detection · Microfluidic and Bio-sensing Technologies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Graduate School of Engineering, Tohoku University 1 , Sendai, Miyagi 980-8579, Japan

Graduate School of Engineering, Toyohashi University of Technology 2 , Toyohashi, Aichi 441-8580, Japan

Department of Applied Chemistry, Faculty of Science, Tokyo University of Science 3 , Tokyo 162-8601, Japan

Faculty of Engineering, Tohoku Gakuin University 4 , Sendai, Miyagi 985-8537, Japan

Institute for Quantum Life Science, National Institutes for Quantum and Radiological Science and Technology 5 , Chiba 263-8555, Japan

Research Center for Food Safety, Graduate School of Agricultural and Life Sciences, The University of Tokyo 6 , Tokyo 113-8657, Japan

Matrix Cell Research Institute Inc. 7 , Ibaraki 300-1232, Japan

Graduate School of Engineering, The University of Tokyo 8 , Tokyo 113-8656, Japan

Funding

Uehara Memorial Foundation · Hitachi Global Foundation · Nakatani Foundation for Advancement of Measuring Technologies in Biomedical Engineering · Adaptable and Seamless Technology Transfer Program Through Target-Driven R and D · Japan Agency for Medical Research and Development · High Energy Accelerator Research Organization

References (25)

Show source-provided references
1. Deep learning for screening COVID-19 using chest X-ray images
2. Magnetic particle spectroscopy for detection of influenza A virus subtype H1N110.1021/acsami.0c00815 ↗
3. Magnetic-nanosensor-based virus and pathogen detection strategies before and during covid-1910.1021/acsanm.0c02048 ↗
4. Development and potential usefulness of the COVID-19 Ag respi-strip diagnostic assay in a pandemic context10.3389/fmed.2020.00225 ↗
5. Magnetic nanoparticle relaxation dynamics-based magnetic particle spectroscopy for rapid and wash-free molecular sensing10.1021/acsami.9b05233 ↗
6. Giant magnetoresistance-based biosensor for detection of influenza A virus10.3389/fmicb.2016.00400 ↗
7. Portable GMR handheld platform for the detection of influenza A virus10.1021/acssensors.7b00432 ↗
8. Integrated platform for detecting pathogenic DNA via magnetic tunneling junction-based biosensors10.1016/j.snb.2016.11.051 ↗
9. Detection of HIV-1 antigen based on magnetic tunnel junction sensors10.1088/1674-1056/ab928d ↗
10. Study of magnetic nanoparticle spectrum for magnetic nanothermometry10.1109/tmag.2015.2434322 ↗
11. Viscous effects on nanoparticle magnetization harmonics10.1016/j.jmmm.2009.10.024 ↗
12. Nonequilibrium magnetic response of anisotropic superparamagnetic nanoparticles and possible artifacts in magnetic particle imaging10.1371/journal.pone.0118156 ↗
13. Determination of dominating relaxation mechanisms from temperature-dependent Magnetic Particle Spectroscopy measurements10.1016/j.jmmm.2018.11.023 ↗
14. Frequency distribution of the nanoparticle magnetization in the presence of a static as well as a harmonic magnetic field10.1118/1.2903449 ↗
15. Nanoparticle temperature estimation in combined ac and dc magnetic fields10.1088/0031-9155/54/19/L01 ↗
16. Magnetic nanoparticle detection by utilizing nonlinear magnetization for sentinel lymph nodes of breast cancer patients10.1109/tmag.2020.3010641 ↗
17. Development of device for quantifying magnetic nanoparticle tracers accumulating in sentinel lymph nodes10.1063/1.5006668 ↗
18. Detection of magnetic nanoparticles using the second-harmonic signal10.1109/tmag.2011.2157805 ↗
19. Virus detection using second harmonics of magnetic nanoparticles10.1002/tee.23613 ↗
20. Changing iron content and excitation field: Comparative study of Synomag ® nanoparticles10.18416/ijmpi.2022.2203053 ↗
21. Dependence of biomolecule detection on magnetic nanoparticle concentration10.1016/j.jmmm.2020.167408 ↗
22. Toward rapid and sensitive detection of SARS-CoV-2 with functionalized magnetic nanoparticles10.1021/acssensors.0c02160 ↗
23. Point-of-need detection of pathogen-specific nucleic acid targets using magnetic particle spectroscopy10.1016/j.bios.2021.113536 ↗
24. Size-isolation of superparamagnetic iron oxide nanoparticles improves MRI, MPI and hyperthermia performance10.1186/s12951-020-0580-1 ↗
25. Detection of 2019 novel coronavirus (2019-nCoV) by real-time RT-PCR10.2807/1560-7917.ES.2020.25.3.2000045 ↗