Research on the diagnosis method of inter-turn short-circuit faults of dry-type air-core reactor winding based on frequency response analysis
Source abstract
Abstract
Inter-turn short circuit fault (ISCF) is the main fault type of dry-type air-core reactors (DARs), and the reactor burnout event caused by winding ISCF seriously threatens the safe and stable operation of the electric power system. In order to effectively curb the further worsening of ISCF in DARs, a fault detection method based on frequency response analysis was proposed. First, the effect of ISCF on the frequency response curve of the windings was investigated based on the distributed parameter model of DARs. Then, four sets of eigenvalues were proposed for ISCF diagnosis based on the influence law and curve data analysis theory. Finally, based on the eigenvalues, the support vector machine model optimized by the sparrow search algorithm was used to effectively classify the degree of ISCF of the reactor, and the accuracy reached 96%. Furthermore, a test platform was built based on the theoretical analysis for experimental verification, and the test results are consistent with the simulation results. Hence, the method proposed in this paper could effectively classify the ISCF and its severity in DARs. The research in this paper could provide effective guidance for the diagnosis of ISCF in DARs.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Power Transformer Diagnostics and Insulation · Machine Fault Diagnosis Techniques · Magnetic Properties and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Hubei Engineering Research Center for Safety Monitoring of New Energy and Power Grid Equipment, Hubei University of Technology 1 , Wuhan 430068, China
Technology Training Center, State Grid Hubei Electric Power Company 2 , Wuhan 430079, China
State Grid Xinjiang Electric Power Co., Ltd EHV Branch Company 3 , Urumqi 830002, China
Funding
Hubei Provincial Natural Science Foundation Innovation Group “Key Technology of New Energy and Grid Equipment Safety” · Science and Technology Project of State Grid
References (24)
Show source-provided references
1. The use of air-core reactors as fault limiting means on high interrupting10.1109/t-aiee.1949.5059962 ↗
2. Thermal simulation and analysis of dry-type air-core reactors based on multi-physics coupling10.3390/en16217456 ↗
3. Study on fault characteristics of layer short circuit of dry-type air-core series reactor10.1155/2022/5429807 ↗
4. Protection scheme for turn-to-turn faults of magnetically controlled shunt reactor based on waveform similarity comparison10.1016/j.epsr.2019.105980 ↗
5. Thermal and electromagnetic combined optimization design of dry type air core reactor10.3390/en10121989 ↗
6. Research on the online measuring technology of inter-turn insulation of dry air-core reactor10.1049/iet-smt.2019.0553 ↗
7. Air-core dry-type shunt reactor protection based on an alternative current alpha plane10.1049/gtd2.12005 ↗
8. Online detection of inter-turn short circuit faults in dry-type air-core reactor10.3233/jae-2012-1494 ↗
9. The study on temperature measurement for the 35 kV dry-type air-core reactor with the embedded optical fiber bragggrating
10. A detailed analysis of hotspots and insulation breakdown phenomena in power inductor windings at high frequency regimes: Overcurrents and overvoltages10.1002/etep.196 ↗
11. 2021
12. 2021
13. 2021
14. Modeling power transformers to support the interpretation of frequency-response analysis10.1109/tpwrd.2011.2164424 ↗
15. Online frequency response analysis of electric machinery through an active coupling system based on power electronics10.3390/s21238057 ↗
16. 2021
17. Suppression measures for overvoltage caused by vacuum circuit breaker switching off 10-kV shunt reactor10.1109/tpwrd.2019.2912663 ↗
18. Piecewise frequency-domain modeling of large power transformer windings for very fast transient overvoltage simulations
19. High-frequency modeling of a three-winding power transformer using sweep frequency response analysis10.3390/en14134009 ↗
20. High voltage dry-type air-core shunt reactors10.1007/s00502-014-0232-y ↗
21. 2016
22. Improved detection of power transformer winding movement by extending the FRA high frequency range10.1109/tpwrd.2005.848674 ↗
23. A novel swarm intelligence optimization approach: Sparrow search algorithm10.1080/21642583.2019.1708830 ↗
24. Support vector machine in machine condition monitoring and fault diagnosis10.1016/j.ymssp.2006.12.007 ↗