Transcranial magnetic stimulation: U-shaped coil design for improved intracranial induced electrical field
Source abstract
Abstract
Transcranial magnetic stimulation (TMS) has been widely used in scientific research and clinical application. In TMS, the stimulation coil generates a focusing induced electrical field in the intracranial target area to achieve neuromodulation. Since different disorders correspond to their specific target areas, in order to avoid non-target tissue being stimulated, the figure-of-eight (FOE) coil with good focusing performance is still the most commonly used magnetic coil. In this paper, the U-shaped coil with multi-parameters is introduced and optimized. The spatial distributions of the intracranial induced electrical field produced by the U-shaped coil are obtained using the finite-element method. Compared to the traditional FOE coil, the U-shaped coil not only has a great advantage in improving focalization but also is beneficial to obtain other improved characteristics. The mathematical relationship between the coil geometric parameters and the intracranial induced electrical field characteristics is analyzed under the constraint of fixed coil power loss. To further improve coil efficiency, the particle swarm optimization (PSO) is adopted to optimize the coil parameters. A real human head modeled as homogeneous and isotropic is occupied in this paper to verify our method, and a traditional FOE coil is used as the reference coil. We also checked the maximum induced charge density on the targeted plane generated by the optimized U-shaped coil to make sure that it will not cause induced neurologic damage.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Transcranial Magnetic Stimulation Studies · Advanced MRI Techniques and Applications · Neuroscience and Neural Engineering
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Wuhan National High Magnetic Field Center, Huazhong University of Science and Technology 1 , Wuhan 430074, China
State Key Laboratory of Advanced Electromagnetic Engineering and Technology, Huazhong University of Science and Technology 2 , Wuhan 430074, China
Funding
The National Key Research and Development Program of China
References (24)
Show source-provided references
1. Electromagnetic mechanism of magnetic nerve stimulation10.1063/1.344421 ↗
2. Calculating the electric field in real human head by transcranial magnetic stimulation with shield plate10.1063/1.3059614 ↗
3. A quasi-static boundary element approach with fast multipole acceleration for high-resolution bioelectromagnetic models10.1109/tbme.2018.2813261 ↗
4. Deep transcranial magnetic stimulation: Modeling of different coil configurations10.1109/tbme.2015.2498646 ↗
5. Preliminary upper estimate of peak currents in transcranial magnetic stimulation at distant locations from a TMS coil10.1109/tbme.2015.2507572 ↗
6. Changes in brain functional networks of insomniacs induced by magnetic stimulation at acupoints10.1109/tasc.2018.2882069 ↗
7. Redesigning existing transcranial magnetic stimulation coils to reduce energy: Application to low field magnetic stimulation10.1088/1741-2552/aaa505 ↗
8. Characteristics of bowl-shaped coils for transcranial magnetic stimulation10.1063/1.4914876 ↗
9. Deep brain transcranial magnetic stimulation using variable “Halo coil” system10.1063/1.4913937 ↗
10. Transcranial magnetic stimulation: Improved coil design for deep brain investigation10.1063/1.3563076 ↗
11. Improved field focalization in transcranial magnetic stimulation of the brain with the utilization of a conductive shield plate in the stimulator10.1109/tbme.2006.870244 ↗
12. Electric field properties of two commercial figure-8 coils in TMS: Calculation of focality and efficiency10.1016/j.clinph.2004.02.019 ↗
13. 1998
14. A novel electric design for electromagnetic stimulation-the Slinky coil10.1109/10.412658 ↗
15. A 3-D differential coil design for localized magnetic stimulation10.1109/10.951519 ↗
16. Simulation study to improve focalization of a figure eight coil by using a conductive shield plate and a ferromagnetic block10.1109/tnsre.2015.2389263 ↗
17. Electric field depth–focality tradeoff in transcranial magnetic stimulation: Simulation comparison of 50 coil designs10.1016/j.brs.2012.02.005 ↗
18. Assessment of the sensitivity to field focalization of various parameters during transcranial magnetic stimulation10.1109/tmag.2007.906396 ↗
19. The need for correct realistic geometry in the inverse EEG problem10.1109/10.797987 ↗
20. Coil design considerations for deep-brain transcranial magnetic stimulation (dTMS)
21. The development of high performance pulsed magnets of the prototype facility of WHMFC10.1109/tasc.2010.2042585 ↗
22. Magnet design and analysis of a 40 tesla long pulse system energized by a battery bank10.1007/s10909-012-0670-z ↗
23. Design and performance of the first dual-coil magnet at the Wuhan National High Magnetic Field Center10.1007/s10909-012-0677-5 ↗
24. The heating of metal electrodes during rapid-rate magnetic stimulation: A possible safety hazard10.1016/0168-5597(92)90077-o ↗