High sensitivity zero-biased magnetic field sensor based on multiphase laminate heterostructures with FeCuNbSiB nanocrystalline soft magnetic alloy
Source abstract
Abstract
In this paper, a high sensitivity zero-biased magnetic field sensor based on multiphase laminate heterostructures consisting of FeCuNbSiB/Terfenol-D (Tb1−xDyxFe2)/PZT (Pb(Zr1-x,Tix)O3)/Terfenol-D/PZT/Ternol-D/FeCuNbSiB (FMPMPMF) is presented, whose ME coupling characteristics and sensing performances have been investigated. Compared to traditional Terfenol-D/PZT/Terfenol-D (MPM) and Terfenol-D/PZT/Terfenol-D/PZT/Terfenol-D (MPMPM) sensors, the zero-biased ME coupling characteristics of FMPMPMF sensor were significantly improved, owing to a build-in magnetic field in FeCuNbSiB/Terfenol-D layers. The optimum zero-biased resonant ME voltage coefficient of 3.02 V/Oe is achieved, which is 1.65 times as great as that of MPMPM and 2.51 times of MPM sensors. The mean value of low-frequency ME field coefficient of FMPMPMF reaches 122.53 mV/cm Oe, which is 2.39 times as great as that of MPMPM and 1.79 times of MPM sensors. Meanwhile, the induced zero-biased ME voltage of FMPMPMF sensor shows an excellent linear relationship to ac magnetic field both at the low frequency (1 kHz) and the resonant frequency (106.6 kHz). Remarkably, it indicates that the proposed zero-biased magnetic field sensor give the prospect of being able to applied to the field of highly sensitive ac magnetic field sensing.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Multiferroics and related materials · Magneto-Optical Properties and Applications · Magnetic Field Sensors Techniques
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Chongqing University Sensors and Instruments Research Center, College of Optoelectronic Engineering, , Chongqing 400044, PR China
Funding
Fundamental Research Funds for the Central Universities · National Natural Science Foundation of China
References (19)
Show source-provided references
1. Nature · 2006 · 442 · 75910.1038/nature05023 ↗
2. Appl. Phys. Lett. · 2013 · 105 · 12290310.1063/1.4896572 ↗
3. J. Appl. Phys. · 2015 · 117 · 17A33110.1063/1.4918688 ↗
4. AIP Advances · 2013 · 3 · 06211510.1063/1.4811369 ↗
5. Appl. Phys. Lett. · 2010 · 96 · 19250210.1063/1.3428774 ↗
6. Appl. Phys. Lett. · 2014 · 105 · 15290210.1063/1.4898039 ↗
7. J. Appl. Phys. · 2015 · 117 · 17D70110.1063/1.4906170 ↗
8. J. Appl. Phys. · 2008 · 103 · 03110110.1063/1.2836410 ↗
9. Appl. Phys. Lett. · 2014 · 104 · 11240110.1063/1.4868983 ↗
10. AIP Advances · 2015 · 5 · 10710110.1063/1.4932512 ↗
11. Nat Mater · 2007 · 6 · 2110.1038/nmat1805 ↗
12. AIP Advances · 2014 · 4 · 11710810.1063/1.4901564 ↗
13. IEEE Trans. Magn. · 2015 · 51 · 2504204
14. J. Appl. Phys. · 2010 · 108 · 09370610.1063/1.3493154 ↗
15. IEEE Trans. Magn. · 2015 · 51 · 2006204
16. Acta Phys. Sinica · 2011 · 60 · 06750110.7498/aps.60.067501 ↗
17. IEEE Trans. Ultrason. Ferroelectr. Freq. · 2003 · 50 · 123610.1109/TUFFC.2003.1244738 ↗
18. J. Appl. Phys. · 2014 · 115 · 17C72610.1063/1.4866089 ↗
19. Sens. Actuators A · 2008 · 141 · 12910.1016/j.sna.2007.08.004 ↗