Study of cavity effect in micro-Pirani gauge chamber with improved sensitivity for high vacuum regime
Source abstract
Abstract
Ultra-low pressure application of Pirani gauge needs significant improvement of sensitivity and expansion of measureable low pressure limit. However, the performance of Pirani gauge in high vacuum regime remains critical concerns since gaseous thermal conduction with high percentage is essential requirement. In this work, the heat transfer mechanism of micro-Pirani gauge packaged in a non-hermetic chamber was investigated and analyzed compared with the one before wafer-level packaging. The cavity effect, extremely important for the efficient detection of low pressure, was numerically and experimentally analyzed considering the influence of the pressure, the temperature and the effective heat transfer area in micro-Pirani gauge chamber. The thermal conduction model is validated by experiment data of MEMS Pirani gauges with and without capping. It is found that nature gaseous convection in chamber, determined by the Rayleigh number, should be taken into consideration. The experiment and model calculated results show that thermal resistance increases in the molecule regime, and further increases after capping due to the suppression of gaseous convection. The gaseous thermal conduction accounts for an increasing percentage of thermal conduction at low pressure while little changes at high pressure after capping because of the existence of cavity effect improving the sensitivity of cavity-effect-influenced Pirani gauge for high vacuum regime.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Mechanical and Optical Resonators · Advanced MEMS and NEMS Technologies · Analytical Chemistry and Sensors
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Electronic and Information Engineering, Xi’an Jiaotong University 1 , Xi’an 710049, P. R. China
Integrated Circuit Advanced Process Center, Institute of Microelectronics, Chinese Academy of Sciences 2 , Beijing 100029, China
Funding
National Natural Science Foundation of China
References (29)
Show source-provided references
1. Journal of Sensors and Sensor Systems · 2017 · 6 · 36710.5194/jsss-6-367-2017 ↗
2. Appl. Phys. Lett. · 2017 · 111 · 11350210.1063/1.4995364 ↗
3. Vacuum · 2007 · 82 · 42010.1016/j.vacuum.2007.08.001 ↗
4. 2015 · 03C103
5. Appl. Phys. Lett. · 2013 · 102 · 16190410.1063/1.4802799 ↗
6. Appl. Phys. Lett. · 2014 · 104 · 12370110.1063/1.4869816 ↗
7. Appl. Phys. Lett. · 2016 · 109 · 12350510.1063/1.4963183 ↗
8. 2015 · 1069
9. 2014 · 676
10. Sens. Actuators, A · 2010 · 163 · 15910.1016/j.sna.2010.08.015 ↗
11. Applied Physics Letters · 2012 · 101 · 18350610.1063/1.4765665 ↗
12. Sens. Actuators, A · 2014 · 216 · 17610.1016/j.sna.2014.05.031 ↗
13. IEEE Trans. Adv. Packag. · 2005 · 28 · 61910.1109/TADVP.2005.858316 ↗
14. Chinese Physics Letters · 2017 · 34 · 02510110.1088/0256-307x/34/2/025101 ↗
15. J. Microelectromech. Syst. · 2008 · 17 · 9310.1109/jmems.2007.912711 ↗
16. Journal of Micromechanics and Microengineering · 2009 · 19 · 04500710.1088/0960-1317/19/4/045007 ↗
17. J. Vac. Sci. Technol., A · 2013 · 31 · 06160410.1116/1.4819783 ↗
18. Vacuum · 2004 · 75 · 16910.1016/j.vacuum.2004.02.002 ↗
19. J. Microelectromech. Syst. · 2017 · PP · 1
20. 2009
21. J. Vac. Sci. Technol., A · 2016 · 34 · 04160110.1116/1.4948527 ↗
22. AIP Adv. · 2017 · 7 · 01531010.1063/1.4975153 ↗
23. Sens. Actuators, A · 2010 · 161 · 10810.1016/j.sna.2010.04.034 ↗
24. IEEE Trans. Ind. Electron. · 2009 · 56 · 108610.1109/tie.2009.2012421 ↗
25. IEEE J. Solid-State Circuits · 1992 · 26 · 199810.1109/4.104194 ↗
26. Vacuum · 2017 · 139 · 6710.1016/j.vacuum.2017.02.016 ↗
27. Sol. Energy · 2013 · 97 · 30510.1016/j.solener.2013.08.035 ↗
28. J. Vac. Sci. Technol., A · 2015 · 33 · 02160110.1116/1.4902340 ↗
29. 2004 · 36.36.31