journal article·2019-07-01Open access

Noise characteristics of a 750-MHz electronically tunable resonator for electron paramagnetic resonance spectroscopy

Ririko Nakaoka, Hiroshi Hirata

AIP Advances· Volume 9· Issue 7

Abstract

This paper describes an experimental investigation of the noise characteristics of a 750-MHz electronically tunable resonator for electron paramagnetic resonance (EPR) spectroscopy. The RF noise of the tunable resonator and its influence on the baseline noise of an EPR spectrum were systematically measured, considering both the noise of varactor diodes used in the impedance matching network of the resonator and noise from the ambient environment. The influence of magnetic field modulation and its amplitude on the baseline noise of the EPR spectrum was also measured. The tunable resonator itself increased the noise level of the spectral baseline of a home-built 750-MHz continuous-wave (CW) EPR spectrometer. A significant decrease in the noise level of the EPR spectral baseline was demonstrated by replacing the varactor diodes in the matching network by a trimmer capacitor, which led to a 6.1-fold improvement in EPR spectrum signal-to-noise ratio.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Electron Spin Resonance Studies · Advanced MRI Techniques and Applications · Atomic and Subatomic Physics Research

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Division of Bioengineering and Bioinformatics, Graduate School of Information Science and Technology, Hokkaido University , North 14, West 9, Kita-ku, Sapporo 060-0814, Japan

Funding

Japan Society for the Promotion of Science

References (21)

Show source-provided references
1. Front. Oncol. · 2017 · 7 · 1010.3389/fonc.2017.00010 ↗
2. Cancer Metastasis Rev. · 2019 · 110.1007/s10555-018-09777-y ↗
3. J. Magn. Reson. · 2017 · 280 · 14910.1016/j.jmr.2017.04.017 ↗
4. Cancer Res. · 2010 · 70 · 642710.1158/0008-5472.can-10-1350 ↗
5. Magn. Reson. Med. · 2016 · 76 · 35010.1002/mrm.25867 ↗
6. Anal. Chem. · 2018 · 90 · 1393810.1021/acs.analchem.8b03328 ↗
7. Sensitivity considerations in microwave paramagnetic resonance absorption techniques10.1002/j.1538-7305.1957.tb02406.x ↗
8. J. Magn. Reson. · 1982 · 47 · 51510.1016/0022-2364(82)90221-9 ↗
9. Rev. Sci. Instrum. · 1987 · 58 · 187910.1063/1.1139536 ↗
10. Noise analysis of EPR spectrometers with cryogenic microwave preamplifiers10.1006/jmra.1995.1052 ↗
11. Noise-immune coil for unshielded magnetic resonance measurements10.1006/jmre.1997.1335 ↗
12. Noise figure limits for circular loop MR coils10.1002/mrm.21948 ↗
13. IEEE Trans. Biomed. Eng. · 2018 · 65 · 112410.1109/TBME.2017.2743232 ↗
14. Appl. Magn. Reson. · 2018 · 49 · 85310.1007/s00723-018-1001-6 ↗
15. Rev. Sci. Instrum. · 2008 · 79 · 12370110.1063/1.3033161 ↗
16. Anal. Chem. · 2009 · 81 · 750110.1021/ac901169g ↗
17. Magn. Reson. Med. · 2001 · 46 · 120910.1002/mrm.1318 ↗
18. J. Magn. Reson. · 2003 · 164 · 23310.1016/s1090-7807(03)00236-2 ↗
19. Rev. Sci. Instrum. · 1986 · 57 · 109510.1063/1.1138663 ↗
20. Rev. Sci. Instrum. · 1990 · 61 · 224810.1063/1.1141400 ↗
21. Rev. Sci. Instrum. · 1991 · 62 · 296910.1063/1.1142191 ↗