Abstract

This letter reports on a method for producing on demand calibrated bubbles in a non-chemically controlled solution using localized micro-electrolysis and ultrasound. Implementing a feedback loop in the process leads to a point source of stable mono-dispersed microbubbles. This approach overcomes the inertial constraints encountered in microfluidics with the possibility to produce from a single to an array of calibrated bubbles. Moreover, this method avoids the use of additional surfactant that may modify the composition of the host fluid. It impacts across a broad range of scientific domains from bioengineering, sensing to environment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Microfluidic and Bio-sensing Technologies · Innovative Microfluidic and Catalytic Techniques Innovation · Ultrasound and Cavitation Phenomena

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Centrale Marseille, LMA 1 Aix Marseille Univ, CNRS, , Marseille, France

Aix-Marseille Université 2 CINaM, CNRS, , UMR 7325, Campus de Luminy, Case 913, 13288 Marseille Cedex 9, France

Funding

Agence Nationale de la Recherche

References (23)

Show source-provided references
1. J. Chem. Phys. · 2014 · 140 · 10470810.1063/1.4867285 ↗
2. J. Appl. Phys. · 2012 · 112 · 06490410.1063/1.4752758 ↗
3. Langmuir · 2016
4. Nature · 2003 · 424 · 83910.1038/nature01939 ↗
5. Phys. Rev. Lett. · 2006 · 9710.1103/PhysRevLett.97.133601 ↗
6. Opt. Lett. · 2010 · 35 · 89810.1364/OL.35.000898 ↗
7. Phys. Rev. Lett. · 2014 · 113 · 13550510.1103/PhysRevLett.113.135505 ↗
8. Photon. Technol. Lett. · 2013 · 25 · 235010.1109/LPT.2013.2283732 ↗
9. Optics Express · 2015 · 23 · 190610.1364/OE.23.001906 ↗
10. Nat Rev Drug Discov. · 2004 · 3 · 52710.1038/nrd1417 ↗
11. Advanced Drug Delivery Reviews · 2008 · 60 · 115310.1016/j.addr.2008.03.005 ↗
12. Eur Radiol. · 2005 · 15 · 141510.1007/s00330-005-2663-7 ↗
13. J. Cerebr. Blood F. Met. · 2012 · 32 · 194810.1038/jcbfm.2012.100 ↗
14. Phys. Rev. B · 2015 · 91 · 02030110.1103/PhysRevB.91.020301 ↗
15. Phys. Rev. Applied · 2015 · 4 · 02400310.1103/PhysRevApplied.4.024003 ↗
16. Soft Matter · 2015 · 11 · 206710.1039/C5SM00113G ↗
17. Eur. Phys. J. E · 2009 · 29 · 12310.1140/epje/i2009-10457-y ↗
18. Nature · 2006 · 442 · 36810.1038/nature05058 ↗
19. Appl. Phys. Lett. · 2013 · 103 · 22310610.1063/1.4836095 ↗
20. Appl. Phys. Lett. · 2016 · 109 · 06410110.1063/1.4960098 ↗
21. 1909
22. J. Acoust. Soc. Am. · 1975 · 99 · 3373
23. J. Fluid Mech. · 1999 · 389 · 13710.1017/S0022112099004899 ↗