Radiometric calibration of optical microscopy and microspectroscopy apparata over a broad spectral range using a special thin-film luminescence standard
Source abstract
Abstract
Application capabilities of optical microscopes and microspectroscopes can be considerably enhanced by a proper calibration of their spectral sensitivity. We propose and demonstrate a method of relative and absolute calibration of a microspectroscope over an extraordinary broad spectral range covered by two (parallel) detection branches in visible and near-infrared spectral regions. The key point of the absolute calibration of a relative spectral sensitivity is application of the standard sample formed by a thin layer of Si nanocrystals with stable and efficient photoluminescence. The spectral PL quantum yield and the PL spatial distribution of the standard sample must be characterized by separate experiments. The absolutely calibrated microspectroscope enables to characterize spectral photon emittance of a studied object or even its luminescence quantum yield (QY) if additional knowledge about spatial distribution of emission and about excitance is available. Capabilities of the calibrated microspectroscope are demonstrated by measuring external QY of electroluminescence from a standard poly-Si solar-cell and of photoluminescence of Er-doped Si nanocrystals.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Silicon Nanostructures and Photoluminescence · Nanowire Synthesis and Applications · Thin-Film Transistor Technologies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Faculty of Mathematics and Physics , Department of Chemical Physics & Optics, Charles University, Ke Karlovu 3, 121 16 Prague 2, Czechia
Funding
Charles University in Prague · Ministry of Education, Youth and Sports
References (23)
Show source-provided references
1. 2012
2. 1994
3. Rev. Sci. Instr. · 1995 · 66 · 352710.1063/1.1145465 ↗
4. J. Microscopy · 2010 · 239 · 20010.1111/j.1365-2818.2010.03366.x ↗
5. J. Luminescence · 2002 · 98 · 1510.1016/S0022-2313(02)00246-6 ↗
6. Nanosci. Methods · 2014 · 3 · 1110.1080/21642311.2014.884288 ↗
7. Appl. Phys. B · 2006 · 83 · 8710.1007/s00340-005-2118-5 ↗
8. Thin Solid Films · 2011 · 520 · 12110.1016/j.tsf.2011.06.084 ↗
9. J. Microscopy · 2004 · 216 · 1510.1111/j.0022-2720.2004.01390.x ↗
10. Opt. Express · 2014 · 22 · 1429310.1364/OE.22.014293 ↗
11. J. Microscopy · 2005 · 219 · 12210.1111/j.1365-2818.2005.01504.x ↗
12. Appl. Phys. Lett. · 2014 · 105 · 24310710.1063/1.4904472 ↗
13. J. Opt. Soc. Am · 1987 · 4 · 33710.1364/JOSAB.4.000337 ↗
14. Adv. Functional Materials · 2008 · 18 · 266610.1002/adfm.200800397 ↗
15. 2010
16. Phys. Rev. B · 2007 · 76 · 08530310.1103/PhysRevB.76.085303 ↗
17. Appl. Phys. A · 2009 · 96 · 18910.1007/s00339-008-4986-0 ↗
18. J. Appl. Phys. · 2007 · 101 · 12311010.1063/1.2749201 ↗
19. Sol. En. Mater. & Sol. Cells · 1996 · 53 · 10310.1016/S0927-0248(98)00016-6 ↗
20. Prog. Photovolt: Res. Appl. · 2009 · 17 · 39410.1002/pip.895 ↗
21. Appl. Phys. Lett. · 1997 · 71 · 119810.1063/1.119624 ↗
22. Phys. Rev. B · 2008 · 78 · 03532710.1103/PhysRevB.78.035327 ↗
23. Nature Nanotech. · 2013 · 8 · 72910.1038/nnano.2013.171 ↗