journal article·2026-02-01Open access

Commutation failure diagnosis of superconducting magnet power supply based on dual-channel CNN

Zhenyu Xue, Liansheng Huang, Xiaojiao Chen, Xiuqing Zhang, Shiying He, Sheng Dou, Ying Zuo

AIP Advances· Volume 16· Issue 2

Abstract

Aiming at the difficultly of identification and low diagnostic accuracy, a superconducting magnet power supply fault diagnosis model based on a dual-channel convolutional neural network is established. The feature expression ability of data from one dimension to two dimensions is enhanced by constructing the first-order derivative Gramian angular difference field, and the squeeze and excitation dilated residual block is introduced to improve the deep feature extraction performance. The fusion-gated bidirectional long short-term memory is designed to weight the time series dependency. Finally, the convolutional block attention module is introduced to optimize the key feature expression effect. According to the experimental results, the accuracy of the established fault diagnosis model is as high as 99.31%, while the accuracy is still 93.52% under the noise interference of −4 dB. The established commutation failure diagnosis model exhibits strong anti-noise performance and high accuracy, which can ensure the reliable operation of the power supply and safe operation of the fusion device.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Machine Fault Diagnosis Techniques · Machine Learning and ELM · Wireless Signal Modulation Classification

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electrical and Information Engineering, Anhui University of Science and Technology 1 , Huainan 232001,

Institute of Plasma Physics, Chinese Academy of Sciences 2 , Hefei 230031,

Funding

National Natural Science Foundation of China

References (24)

Show source-provided references
1. Implementation and design of the control system for poloidal field power supply10.1016/j.fusengdes.2020.111878 ↗
2. Design and implementation of DC pulsed power supply employing self-excited induction generators and flywheels for toroidal field coils of a tokamak device, PLATO10.1109/tasc.2020.2981075 ↗
3. Study on the changes in the reverse recovery characteristics of high-power thyristor under 14.1 MeV fusion neutron irradiation10.1016/j.fusengdes.2024.114744 ↗
4. Preliminary design of the poloidal field AC/DC converter system for the ITER coil power supply10.13182/fst13-a24094 ↗
5. The voltage response test of ITER PF converter bridge10.1016/j.fusengdes.2019.111432 ↗
6. Review of hybrid multilevel converter topologies utilizing thyristors for HVDC applications10.1109/tpel.2020.2997961 ↗
7. Design and test results for the PF power supply system of EAST10.13182/fst08-a1916 ↗
8. Safety and interlock system for poloidal field power supply based on EPICS10.1016/j.fusengdes.2025.114823 ↗
9. Design of the new generation EAST poloidal field magnet power supply10.1016/j.fusengdes.2025.115004 ↗
10. Design and analysis of magnetic compression magnet casing based on optimized equivalent material method10.1016/j.fusengdes.2025.114856 ↗
11. The strategy of continuous commutation failure suppression by combining turn-off angle compensation and dynamic nonlinear VDCOL10.3390/su16052145 ↗
12. Diagnosis of commutation failures in HVDC system based on voltage or current of the converter valve10.4028/www.scientific.net/amr.960-961.738 ↗
13. Fault diagnosis of commutation failure using wavelet transform and wavelet neural network in HVDC transmission system10.1109/tim.2021.3115574 ↗
14. A suppression method of commutation failure in LCC-UHVDC systems based on the dynamic tracking of the turn-off angle setting value10.3390/electronics13071353 ↗
15. A detection method for HVDC commutation failure based on the variation rate of commutation inductance energy10.1049/gtd2.12403 ↗
16. A fast and high-accurate commutation failure identification method for LCC-HVDC system10.1049/hve2.12400 ↗
17. Fault diagnosis of multi-terminal HVDC transmission line based on parallel convolutional neural network10.7500/AEPS20191124003 ↗
18. Recurrent graph convolutional network-based multi-task transient stability assessment framework in power system10.1109/access.2020.2991263 ↗
19. Design of master control system for poloidal field power supply based on real-time Linux10.16568/j.0254-6086.201801015 ↗
20. Hardware-in-the-loop simulation of the EAST PF converter for PF control system upgrade10.1016/j.fusengdes.2016.07.020 ↗
21. Comprehensive review of commutation failure in HVDC transmission systems10.1016/j.epsr.2021.107768 ↗
22. Analysis and improvement of the multiple controller interaction in LCC-HVDC for mitigating repetitive commutation failure10.1109/tpwrd.2020.3017802 ↗
23. Hybrid transformer for anomaly detection on railway HVAC systems through feature ensemble of spatial–temporal with multi-channel GADF images10.1007/s42835-024-01844-5 ↗