Extended curvature birdcage coil design for localized magnetic field in 9.4 T MRI for multiple mouse imaging
Source abstract
Abstract
Magnetic resonance imaging (MRI) for preclinical analysis is useful for testing medical procedures, therapies, and drug development. Preclinical MRI uses small animals, such as mice, for multiple studies. Preclinical studies are often needed to control target mouse models with different parameters; thus, performing simultaneous MRIs is desired to reduce study time and provide a fair comparison. In this study, we propose a variation of a birdcage coil that is capable of providing the same field intensity for each mouse compared to a traditional birdcage coil configuration. The arrangement of the proposed birdcage coil produces a uniform and strongly localized magnetic |B1|-field in each of the four target mice. The design involves rotating the legs of the birdcage coil so that the current distribution produces a uniform field inside each mouse. Electromagnetic simulations were performed to validate the proposed design. The proposed design exhibited a better field intensity than the reference linear, circularly polarized mode birdcage coils and an eight-channel loop array coil. The proposed customized birdcage coil arrangement promises a better field intensity and uniformity across multiple mouse imaging using 9.4 T preclinical MRI scanners.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advanced MRI Techniques and Applications · Advanced NMR Techniques and Applications · Functional Brain Connectivity Studies
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Neuroscience Research Institute, Gachon University 1 , Incheon 21988, Republic of Korea
Department of Health Sciences and Technology, GAIHST, Gachon University 2 , Incheon 21999, Republic of Korea
Non-clinical Center, KBIO Osong Medical Innovation Foundation 3 , Osong, Cheongju-si, Chungbuk 28160, Republic of Korea
Department of Biomedical Engineering, Gachon University 4 , Seongnam 13120, Republic of Korea
Funding
Osong Medical Innovation Foundation R&D, Republic of Korea’s Ministry of Health and Welfare
References (25)
Show source-provided references
1. Preclinical magnetic resonance imaging and systems biology in cancer research: Current applications and challenges10.1016/j.ajpath.2012.09.024 ↗
2. A multicenter preclinical MRI study: Definition of rat brain relaxometry reference maps10.3389/fninf.2020.00022 ↗
3. Translating preclinical MRI methods to clinical oncology10.1002/jmri.26731 ↗
4. Use of a clinical MRI scanner for preclinical research on rats10.1007/s12194-008-0038-x ↗
5. Magnetic resonance imaging of marmoset monkeys10.1093/ilar/ilaa029 ↗
6. MRI monitoring of macaque monkeys in neuroscience: Case studies, resource and normative data comparisons10.1016/j.neuroimage.2021.117778 ↗
7. Animal studies in clinical MRI scanners: A custom setup for combined fMRI and deep-brain stimulation in awake rats10.1016/j.jneumeth.2021.109240 ↗
8. Medical imaging in new drug clinical development10.3978/j.issn.2072-1439.2010.11.10 ↗
9. In vivo molecular imaging in preclinical research10.1186/s42826-022-00142-3 ↗
10. Biomedical imaging in experimental models of cardiovascular disease10.1161/CIRCRESAHA.122.320306 ↗
11. Accurate molecular imaging of small animals taking into account animal models, handling, anaesthesia, quality control and imaging system performance10.1186/s40658-015-0135-y ↗
12. Decoupled circular-polarized dual-head volume coil pair for studying two interacting human brains with dyadic fMRI10.1002/mrm.23313 ↗
13. Multiple-mouse magnetic resonance imaging with cryogenic radiofrequency probes for evaluation of brain development10.1016/j.neuroimage.2022.119008 ↗
14. Multiple-mouse MRI with multiple arrays of receive coils10.1002/mrm.22236 ↗
15. Multiple mouse biological loading and monitoring system for MRI10.1002/mrm.20215 ↗
16. Simultaneous functional MRI of two awake marmosets10.1038/s41467-021-26976-4 ↗
17. RF coils: A practical guide for nonphysicists10.1002/jmri.26187 ↗
18. A review on the RF coil designs and trends for ultra high field magnetic resonance imaging10.13104/imri.2020.24.3.95 ↗
19. Computational analysis of overlapping birdcage coil for artificial circular-polarized mode in magnetic resonance imaging10.3938/jkps.76.436 ↗
20. Recent progress in birdcage RF coil technology for MRI system10.3390/diagnostics10121017 ↗
21. A fast and accurate simulator for the design of birdcage coils in MRI10.1007/BF02693842 ↗
22. A simple analytical solution for the designing of the birdcage RF coil used in NMR imaging applications10.3390/app10072242 ↗
23. Generalized electrical analysis of low-pass and high-pass birdcage resonators10.1016/0730-725x(91)90428-o ↗
24. Development of novel whole-body exposure setups for rats providing high efficiency, National Toxicology Program (NTP) compatibility and well-characterized exposure10.1088/0031-9155/51/20/009 ↗
25. Hybrid active and passive local shimming (HAPLS) for two-region MRI10.1002/mrm.29542 ↗