journal article·2023-10-01Open access

Investigating the electric field distribution in the human brain model induced by a high focality transcranial magnetic coil

Yong Wang, Yonghui Yang, Yihao Qi, Enzhong Gong, Haiyang Zhang, Liantao Shi, Zhengguo Li

AIP Advances· Volume 13· Issue 10

Abstract

Transcranial magnetic stimulation (TMS) is a noninvasive neuromodulation technique for treating various neurological disorders. The geometry of the TMS coil determines the focality, stimulation field strength, and stimulation depth of the induced electric field. In this paper, we introduce a novel coil, named the eccentric folding coil (EFC). We used Sim4Life, a three-dimensional human tissue medical electromagnetic simulation software, and the brain models of the subjects from the population head model repository to conduct finite element simulations of the eccentric folding coil, circular coil, and figure-eight coil, implying that the largest EFC has a focal area of 19.5 cm2 less than the smallest circular coil, and the EFC of any size has a smaller focal area than the figure-8 coil of the same size. Furthermore, we stimulated the model from three directions with the coil and measured the electric field responses of the model, confirming that stimulation varied in different directions. Additionally, we applied EFC to four representative human models and found that the electric field in different subjects’ brains differed by 3.03 mm in stimulation depth and 12.9 cm2 in focal area, suggesting that personalized human head modeling and electromagnetic analysis are essential for TMS treatment. In the future, we will explore using different types of TMS devices for patients with different conditions to achieve more precise and customized treatment.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Transcranial Magnetic Stimulation Studies · Advanced MRI Techniques and Applications · Functional Brain Connectivity Studies

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Institute for Carbon-Neutral-Technology, Shenzhen Polytechnic University 1 , Shenzhen 518055, China

School of Electronics and Information Engineering 2 , Anshan 114051, China

, University of Science and Technology Liaoning 2 , Anshan 114051, China

Funding

Science and Technology Planning Project of Shenzen Municipality · Shenzhen International Cooperation Research Project

References (23)

Show source-provided references
1. Modulation of learning and hippocampal, neuronal plasticity by repetitive transcranial magnetic stimulation (rTMS)10.1002/bem.20211 ↗
2. Measurement and modeling of the effects of transcranial magnetic stimulation on the brain10.1109/tmag.2020.3008554 ↗
3. Optimal design of transcranial magnetic stimulation coil with iron core10.1088/1741-2552/ac65b3 ↗
4. Non-invasive magnetic stimulation of human motor cortex10.1016/s0140-6736(85)92413-4 ↗
5. Localized stimulation of neural tissues in the brain by means of a paired configuration of time-varying magnetic fields10.1063/1.342181 ↗
6. Efficacy of add-on bilateral transcranial magnetic stimulation with a double-cone coil in patients with treatment resistant depression and comorbid anxiety: Evidence from real-world clinical practice10.1016/j.brs.2021.10.047 ↗
7. Eccentric figure-eight coils for transcranial magnetic stimulation10.1002/bem.21886 ↗
8. Improved field localization in transcranial magnetic stimulation of the brain with the utilization of a conductive shield plate in the stimulator10.1109/TBME.2006.870244 ↗
9. Electric field depth-focality tradeoff in transcranial magnetic stimulation: Simulation comparison of 50 coil designs10.1016/j.brs.2012.02.005 ↗
10. How coil-cortex distance relates to age, motor threshold, and antidepressant response to repetitive transcranial magnetic stimulation10.1176/jnp.12.3.376 ↗
11. Transcranial magnetic stimulation: U-Shaped coil design for improved intracranial induced electrical field10.1063/1.5132412 ↗
12. The human connectome Project: A data acquisition perspective10.1016/j.neuroimage.2012.02.018 ↗
13. Impact of non-brain anatomy and coil orientation on inter- and intra-subject variability in TMS at midline10.1016/j.clinph.2018.04.749 ↗
14. Distance-adjusted motor threshold for transcranial magnetic stimulation10.1016/j.clinph.2007.04.004 ↗
15. A theoretical calculation of the electric field induced in the cortex during magnetic stimulation10.1016/0168-5597(91)90103-5 ↗
16. Brain stimulation using electromagnetic sources: Theoretical aspects10.1016/s0006-3495(92)81587-4 ↗
17. Compilation of the dielectric properties of body tissues at RF and microwave frequencies
18. Conditions for numerically accurate TMS electric field simulation10.1016/j.brs.2019.09.015 ↗
19. Coil design considerations for deep transcranial magnetic stimulation10.1016/j.clinph.2013.11.038 ↗
20. Focality of the induced E-field is a contributing factor in the choice of TMS parameters: Evidence from a 3D computational model of the human brain10.3390/brainsci10121010 ↗
21. The development and modelling of devices and paradigms for transcranial magnetic stimulation10.1080/09540261.2017.1305949 ↗
22. PTMS31: Comparative electric field characteristics of deep transcranial magnetic stimulation coils10.1016/s1388-2457(11)60684-6 ↗
23. Safety, ethical considerations, and application guidelines for the use of transcranial magnetic stimulation in clinical practice and research10.1016/j.clinph.2009.08.016 ↗