Abstract
A transportable, compact, accelerator-based neutron source is under development at Xi’an Jiaotong University. At the heart of the linear accelerator is a radio-frequency quadrupole (RFQ) unit that has been designed to accelerate a proton beam from 30 keV to 2.5 MeV with a peak current of 12 mA and a duty factor of 3%. Recently, the manufacturing of the RFQ cavity has been completed. Cavity tuning, including field unevenness, resonant frequency, and rf coupling coefficient, was carried out after finishing brazing and assembly. The quadrupole perturbative component was controlled within ±2.0%, and the two dipole components were about ±2.5%. The value of the intrinsic Q was 9609, 89% of that of the theoretical simulation. We have completed the installation of the RFQ experimental setup and performed beam commissioning experiments. The output beam current reached 10.6 mA with a transmission efficiency of 93.8%.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Particle accelerators and beam dynamics · Particle Accelerators and Free-Electron Lasers · Magnetic confinement fusion research
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
School of Nuclear Science and Technology, School of Energy and Power Engineering, Xi’an Jiaotong University 1 , Xi’an 710049, China
XJTU-Huzhou Neutron Science Laboratory 2 , Science Valley Medium-sized Building #1, Huzhou 313000, Zhejiang, China
Funding
National Natural Science Foundation of China · State Key Laboratory of Nuclear Physics and Technology, Peking University
References (15)
Show source-provided references
1. Design of a compact RFQ linac for the transportable neutron source10.1016/j.nima.2022.167254 ↗
2. Study and design of the coupled cavity with ladder RFQ and IH DTL structure for transportable neutron source10.1016/j.nima.2023.168645 ↗
3. Research opportunities with compact accelerator-driven neutron sources10.1016/j.physrep.2016.07.007 ↗
4. Development of accelerator-driven transportable neutron source for non-destructive inspection of concrete construct
5. Development and beam commissioning of a continuous-wave window-type radio-frequency quadrupole10.1103/physrevaccelbeams.22.030102 ↗
6. Radio frequency measurements and tuning of the China Material Irradiation Facility RFQ10.1016/j.nima.2018.02.047 ↗
7. A 3-MeV RFQ accelerator for the Compact Pulsed Hadron Source at Tsinghua University10.1016/j.phpro.2012.03.006 ↗
8. 2008
9. CST, https://www.cst.com.
10. Field tuning and rf measurements of the four-vane radio frequency quadrupole with ramped inter-vane voltage10.1103/physrevaccelbeams.22.020102 ↗
11. rf measurements and tuning of the 750 MHz radio frequency quadrupole10.1103/physrevaccelbeams.20.080102 ↗
12. Advanced RF design and tuning methods of RFQ for high intensity proton linacs
13. RF design and tuning of a deuteron RFQ for detecting impurity deposition on a tokamak10.1088/1748-0221/17/01/p01030 ↗
14. Numerical studies on RF tuning of an RFQ in a simulation environment using a tuning program10.1016/j.nima.2021.165021 ↗
15. Design and experiments of a compact electrostatic low energy beam transport with a double Einzel-lens for a transportable neutron source10.1063/5.0160376 ↗