Effects of surface roughness on DC and AC surface flashover performances of epoxy composites in SF6/N2 mixtures
Source abstract
Abstract
Surface flashover of the epoxy insulator is one of the urgent insulation issues in SF6/N2 filled gas-insulated equipment, causing irreversible insulation failure and harming the secure operation of power systems. However, the effects of surface roughness, which has always been changed in actual equipment, on flashover performances have not been comprehensively illustrated until now. In this work, the DC and AC surface flashover voltages of roughed epoxy specimens with a roughness range of 1–7 μm are investigated in 30%SF6–70%N2, and some supporting analysis measurement, including trap, conductivity, surface charging, and partial discharge has been carried out to clarify the how surface roughness affects flashover under steady or transient electric fields. The DC and AC flashover voltages of 7 μm roughness specimens are 28.34 and 16.85 kV, respectively, exhibiting a 28.01% increase compared to those of 1 μm roughness specimens under DC conditions, but they decrease by 12.60% under AC field. The roughed surface introduces shallow traps, inducing charge dissipation by increasing surface conductivity. Moreover, the extended discharge path can also elevate flashover voltage. Both surface charge transport and extended path effects cause DC flashover voltage to increase with roughness. Under AC conditions, partial discharge rather than surface charging dominates the flashover under the transient field, and partial discharge is accelerated by protrusions on the epoxy surface, leading to a decrease in AC flashover voltage with roughness. These findings enable the development of a roughness control strategy for practice insulators in gas-insulated equipment.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: High voltage insulation and dielectric phenomena · Electrostatic Discharge in Electronics · Power Transformer Diagnostics and Insulation
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Electric Power Research Institute, State Grid Anhui Electric Power Company Limited 1 , Hefei 230601,
State Grid Anhui Electric Power Company Limited 2 , Hefei 230041,
DC Technical Center of State Grid 3 , Xicheng, Beijing 100032,
Key Laboratory of Engineering Dielectrics and Its Application, Ministry of Education, Harbin University of Science and Technology 4 , Harbin 150080,
Funding
Science and Technology Project of State Grid Anhui Provincial Electric Co., Ltd.
References (24)
Show source-provided references
1. China’s 10-year progress in DC gas-insulated equipment: From basic research to industry perspective10.23919/ien.2022.0050 ↗
2. SF6-alternative gases for application in gas-insulated switchgear10.1088/1361-6463/aab314 ↗
3. Green gas to replace SF6 in electrical grids10.1109/mpe.2016.2542645 ↗
4. Fluoronitrile/CO2 mixture as an eco-friendly alternative to SF6 for medium voltage switchgears10.1109/tdei.2018.007146 ↗
5. The mechanism of EP/SiC coating modulated DC flashover characteristics of epoxy composites in SF6/N2 mixtures10.1088/1361-6463/ad3bc1 ↗
6. Surface flashover in 50 years: Theoretical models and competing mechanisms10.1049/hve2.12340 ↗
7. Surface flashover in 50 years: II. Material modification, structure optimisation, and characteristics enhancement10.1049/hve2.12489 ↗
8. Surface discharge initiated by immobilized metallic particles attached to gas insulated substation insulators: Process and features10.1109/tdei.2011.5931067 ↗
9. Temperature dependent surface potential decay and flashover characteristics of epoxy/SiC composites10.1109/tdei.2017.006872 ↗
10. Gas–solid interface charge characterisation techniques for HVDC GIS/GIL insulators10.1049/hve.2019.0289 ↗
11. Field-dependent charging phenomenon of HVDC spacers based on dominant charge behaviors10.1063/1.5096228 ↗
12. Tailoring insulation surface conductivity for surface partial discharge mitigation10.1063/5.0050456 ↗
13. Simulation of DC surface flashover of epoxy composites in compressed nitrogen10.1063/5.0059594 ↗
14. Influence mechanism of UVIV on DC surface flashover performances of silicone rubber: From molecule modification to macroscopic characteristics improvement10.1016/j.apsusc.2023.157786 ↗
15. Unravelling surface traps dominated direct-current surface charging and discharging mechanisms10.1016/j.surfin.2025.106518 ↗
16. Enhanced surface flashover strength in vacuum of polymethylmethacrylate by surface modification using atmospheric-pressure dielectric barrier discharge10.1063/1.4893884 ↗
17. Flashover of insulators in vacuum: The last twenty years10.1109/tdei.2015.004702 ↗
18. Effect of surface roughness on flashover characteristics of silicone rubber10.1016/j.elstat.2019.04.004 ↗
19. Mechanism of vacuum flashover on surface roughness10.1088/1361-6463/ab05a0 ↗
20. Effects of surface roughness on surface charge accumulation characteristics and surface flashover performance of alumina-filled epoxy resin spacers10.1063/1.5043239 ↗
21. Superior capacitive energy storage at high temperature of all-organic aromatic polymer via enhancing conjugate angle between benzene rings10.1021/acsami.4c14831 ↗
22. Investigation of temperature-dependent DC breakdown mechanism of EP/TiO2 nanocomposites10.1063/5.0097351 ↗
23. Surface flashover performance of epoxy resin microcomposites improved by electron beam irradiation10.1016/j.apsusc.2017.02.093 ↗
24. Enhanced DC surface discharge characteristics of epoxy composites treated by dielectric barrier discharge plasma fluorination and its mechanisms10.1016/j.apsusc.2024.161489 ↗