journal article·2024-02-01Open access

Characteristics of blood flow velocity in the radial artery and finger capillaries using magnetoplethysmogram and photoplethysmogram

Sang-Suk Lee, Rak-Gun Choi, Won-Tae Kim, Myung-Woo Shin, Jong-Gu Choi, Mahbub Hasan, Byungjo Jung

AIP Advances· Volume 14· Issue 2

Abstract

The Hall element and optical sensor, which can detect the magnetic field change caused by the minute fluctuations of the permanent magnet according to the periodic movement of the radial artery and the light absorption and reflection intensity according to the change in wrist blood flow, respectively, are used as key elements in digital healthcare devices. The pulse waves of the radial artery inside the wrist were measured and analyzed using a clip-type pulsimeter, magnetoplethysmogram (MPG). The pulse wave, which is the change in blood flow obtained by photoplethysmogram (PPG), was measured on the dorsal side of the wrist or the fingers simultaneously with MPG. The ABFV (artery blood flow velocity) is a few ten cm/s as DH (distance between MPG and PPG) divided by ΔT(a) which is the time difference between the first peaks of MPG and PPG waveforms on the dorsal side of the wrist. The PBFV (peripheral blood flow velocity) is a few mm/s as LH (hand length) divided by ΔT(p), which is the time difference between the first peak of MPG waveform and the third peak PPG waveform on the finger. For four subjects of 20s, SPWV was approximately 0.98∼1.19 m/s, ABFV in the radial artery was approximately 0.40∼0.44 m/s, and finger capillary PBFV was approximately 6.3∼8.6 cm/s. These results show reasonable values similar to the blood velocity of many blood vessels flowing through the human body.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Non-Invasive Vital Sign Monitoring · Hemodynamic Monitoring and Therapy · Cardiovascular Health and Disease Prevention

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Digital Healthcare Engineering, College of Health Sciences, Sangji University 1 , Wonju 26339, South Korea

Department of Biochemistry and Molecular Biology, Bangabandhu Sheikh Mujibur Rahman Science and Technology University 2 , Gopalganj, Bangladesh

School of Biomedical Engineering, Yonsei University 3 , Wonju 26493, South Korea

Funding

Ministry of Education

References (14)

Show source-provided references
1. Khidi, The future of digital healthcare, https://www.khidi.or.kr/news/201602/2.pdf.
2. Front Physiol. · 2020 · 11 · 108510.3389/fphys.2020.01085 ↗
3. J. Korean. Magn. Soc. · 2022 · 32 · 26410.4283/jkms.2022.32.6.264 ↗
4. Sensors · 2013 · 13 · 471410.3390/s130404714 ↗
5. Sensors · 2023 · 23 · 168410.3390/s23031684 ↗
6. J. Magn. · 2011 · 16 · 44910.4283/jmag.2011.16.4.449 ↗
7. J. Korean Magn. Soc. · 2013 · 23 · 13510.4283/JKMS.2013.23.4.135 ↗
8. New Phys.: Sae Mulli · 2020 · 70 · 89610.3938/npsm.70.896 ↗
9. J. Korean Magn. Soc. · 2019 · 29 · 17710.4283/JKMS.2019.29.5.177 ↗
10. 2006
11. Physiol. Meas. · 2007 · 28 · R110.1088/0967-3334/28/3/r01 ↗
12. J. Korean Magn. Soc. · 2023 · 33 · 6910.4283/jkms.2023.33.2.069 ↗
13. New Phys.: Sae Mulli · 2023 · 73 · 76910.3938/npsm.73.769 ↗
14. IEEE Trans. Magn. · 2011 · 47 · 306310.1109/tmag.2011.2155044 ↗