journal article·2024-02-01Open access

Sedimentation evaluation of high-viscosity linear polysiloxane-based magnetorheological fluids using automated vertical axis inductance monitoring system

Young T. Choi, Pablo Sztein, Gregory Hiemenz, Norman M. Wereley

AIP Advances· Volume 14· Issue 2

Abstract

The sedimentation evaluation of magnetorheological fluids (MRFs) is a key component to developing successful commercial MRF-based engineering applications. In this study, the long-term sedimentation stability of highly stable high-viscosity linear polysiloxane-based MRFs (HVLP MRFs) was experimentally investigated by using an automated vertical axis inductance monitoring system (AVAIMS). The sedimentation evaluation of the HVLP MRFs with high particle loadings up to 45 vol% was tracked for 295 days, and the four different sedimentation zones such as supernatant, original concentration, variable concentration, and sediment were identified. To this end, the automated identification method to determine the sedimentation zone boundaries of highly stable MRFs was proposed. Three HVLP MRF samples with two different high particle loadings of 35 vol% and 45 vol% and two different high carrier viscosities of 5k and 10k cSt were selected as testing samples and one commercial MRF with a particle loading of 40 vol% (i.e., LORD MRF-140CG) also was tested as a baseline.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Vibration Control and Rheological Fluids · Hydraulic and Pneumatic Systems · Characterization and Applications of Magnetic Nanoparticles

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Department of Aerospace Engineering, University of Maryland 1 , College Park, Maryland 20742, USA

Innovital Systems, Inc. 2 , Calverton, Maryland 20705, USA

References (6)

Show source-provided references
1. Characterization of stratification for an opaque highly stable magnetorheological fluid using vertical axis inductance monitoring system10.1063/1.4918629 ↗
2. Long term stability of magnetorheological fluids using high viscosity linear polysiloxane carrier fluids10.1088/0964-1726/25/7/075006 ↗
3. LORD Corperation · 2023
4. Vertical axis inductance monitoring system to measure stratification in a column of magnetorheological fluid10.1109/TMAG.2016.2606345 ↗
5. Monitoring sedimentation of magnetorheological fluids using a vertical axis monitoring system with a low aspect ratio sensor coil10.1088/1361-665x/aaf757 ↗
6. Testing and analysis of magnetorheological fluid sedimentation in a column using a vertical axis inductance monitoring system10.1088/0964-1726/25/4/04lt01 ↗