Design of hollow tapered PMMA polymeric microneedles for enhanced structural stability and drug delivery efficiency
Source abstract
Abstract
Microneedles have emerged as a promising alternative to conventional, or so-called hypodermic, needles for transdermal drug delivery. A meticulous design of microneedle geometry is crucial for balancing mechanical stability and fluid flow of drugs through these microneedles. This research paper analyzes the mechanical performance and fluid flow behavior of hollow cylindrical tapered shaped microneedles with polymethyl methacrylate, a biocompatible polymer, as material, considering its mechanical properties and also the material being widely used in biomedical applications. The finite element analysis tool is used to enhance the microneedle design by varying the outer base radius and tip radii to mitigate the von Mises stress that is exhibited during axial load and bending load conditions. In addition, microfluidic analysis is to assess the fluid flow behavior through the hollow microneedles, measuring the flow rates of fluids (water, glucose, and insulin).Simulated results reveal that an axial stress of 3.26 × 106 N/m2 and bending stress of 2.31 × 107 N/m2 were reported, which are below the yield strength of the material and satisfy the criteria for successful microneedle penetration. Flow rate analysis of water reports that 834.42 μl/min and 5396.94 μl/min and for glucose as 412 μl/min and 3648 μl/min, and that of insulin as 834 μl/min and 5244 μl/min for applied inlet pressure of 10 and 100 kPa, respectively. The flow rates reveal that water and insulin exhibit nearly identical flow rates, indicating that the proposed microneedles are capable of efficiently delivering viscous fluids.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Advancements in Transdermal Drug Delivery · Bee Products Chemical Analysis · Advanced Drug Delivery Systems
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
References (33)
Show source-provided references
1. Transdermal drug delivery10.1038/nbt.1504 ↗
2. Microfabricated needles for transdermal delivery of macromolecules and nanoparticles: Fabrication methods and transport studies10.1073/pnas.2331316100 ↗
3. Biodegradable polymer microneedles: Fabrication, mechanics and transdermal drug delivery10.1016/j.jconrel.2005.02.002 ↗
4. Finite element analysis of polymer microneedle for transdermal drug delivery10.1016/j.matpr.2020.05.549 ↗
5. Microneedle-based drug delivery systems: Microfabrication, drug delivery, and safety10.3109/10717541003667798 ↗
6. Design and optimization of hollow microneedle spacing for three materials using finite element methods10.1038/s41598-024-82564-8 ↗
7. Microneedles for drug and vaccine delivery10.1016/j.addr.2012.04.005 ↗
8. Microneedle optimization: Toward enhancing microneedle's functionality and breaking the traditions10.1002/sstr.202400121 ↗
9. Current Trends in Polymer Microneedle for Transdermal Drug Delivery10.1016/j.ijpharm.2020.119673 ↗
10. Microfabricated microneedles: A novel approach to transdermal drug delivery10.1021/js980042+ ↗
11. Insertion of microneedles into skin: Measurement and prediction of insertion force and needle fracture force10.1016/j.jbiomech.2003.12.010 ↗
12. Polymer microneedles for controlled-release drug delivery10.1007/s11095-006-0028-9 ↗
13. The finite element analysis research on microneedle design strategy and transdermal drug delivery system10.3390/pharmaceutics14081625 ↗
14. Study on mechanical properties for modeling and simulation of microneedles for medical applications10.4028/www.scientific.net/AMM.454.86 ↗
15. Biodegradable polymeric insulin microneedles – a design and materials perspective review10.1080/10717544.2023.2296350 ↗
16. Optimal microneedle design for drug delivery based on insertion force experiments with variable geometry10.1007/s12555-019-0220-8 ↗
17. Continuous monitoring of diabetes with an integrated microneedle biosensing device through 3D printing10.1038/s41378-021-00302-w ↗
18. Design, fabrication, and penetration assessment of polymeric hollow microneedles with different geometries10.1007/s00170-024-13344-x ↗
19. Mechanical and fluidic analysis of hollow side-open and outer-grooved design of microneedles10.1016/j.mtcomm.2021.102940 ↗
20. Producing hollow polymer microneedles using laser ablated molds in an injection molding process10.1115/1.4051456 ↗
21. Microneedle-mediated transdermal bacteriophage delivery10.1016/j.ejps.2012.06.012 ↗
22. Polymeric-based microneedle arrays as potential platforms in the development of drugs delivery systems10.1016/j.jare.2020.07.017 ↗
23. Modeling of microneedle arrays in transdermal drug delivery applications10.3390/pharmaceutics15020358 ↗
24. Design and analyses of a transdermal drug delivery device10.3390/s19235090 ↗
25. Painless drug delivery through microneedle-based transdermal patches featuring active infusion10.1109/tbme.2007.906492 ↗
26. Design, fabrication and analysis of silicon hollow microneedles for transdermal drug delivery system for treatment of hemodynamic dysfunctions10.1007/s10558-010-9100-5 ↗
27. Design and optimization of a microneedle with skin insertion analysis for transdermal drug delivery applications10.1016/j.jddst.2021.102477 ↗
28. Effect of hollow microneedle geometry structure on mechanical stability and microfluidic flow for transdermal drug delivery applications10.1007/s10404-023-02636-5 ↗
29. Design and scalable fabrication of hollow SU-8 microneedles for transdermal drug delivery10.1109/jsen.2018.2840335 ↗
30. Microneedles’ device: Design, fabrication, and applications10.3390/macromol4020019 ↗
31. Design and characterization of 3D-printed hollow microneedle arrays for transdermal insulin delivery10.1063/5.0204216 ↗
32. A 3D-printed microfluidic-enabled hollow microneedle architecture for transdermal drug delivery10.1063/1.5127778 ↗
33. Fabrication methods of microneedles with polymeric materials10.1007/s11814-024-00314-y ↗