Thin grain oriented electrical steel for PWM voltages fed magnetic cores
Source abstract
Abstract
This paper reports on performances of high permeability grain oriented electrical steel when used in association with power electronic switching devices. Loss measurement results obtained from the Epstein test, using sinusoidal or various PWM voltages in medium frequency range, show that for both studied thicknesses (HGO 0.23mm and HGO 0.18mm), comparing performances at a fixed induction level between the various situations may not be the most convenient method. The effect of magnetic domain refinement has been investigated. After having shown the interest of lowering the thickness, an alternative way of looking at losses is proposed that may help to design the magnetic core when it comes to the matter of reducing size in considering frequency and magnetization levels.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Magnetic Properties and Applications · Silicon Carbide Semiconductor Technologies · Induction Heating and Inverter Technology
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Research & Technology 1 , Thyssenkrupp Electrical Steel GmbH, 45881 Gelsenkirchen, Germany
Laboratoire L2EP, Université Lille 2 , Cité Scientifique, 59655 Villeneuve d’Ascq, France
References (4)
Show source-provided references
1. https://www.thyssenkrupp-steel.com/en/company/business-units/electrical-steel/.
2. Influence of PWM waveform parameters on the breakdown of harmonic losses in electrical steels10.1016/0304-8853(96)00096-0 ↗
3. Iron losses in a medium-frequency transformer operated in a high-power DC–DC converter10.1109/tmag.2013.2283733 ↗
4. Intelligent solid state transformer