journal article·2021-05-01Open access

Prediction and experimental verification of erosion resistance of gas switch electrode materials

Cheng Luo, Peitian Cong, Tianyang Zhang, Xiangli Zhong, Weixi Luo

AIP Advances· Volume 11· Issue 5

Abstract

The gas spark switch is the most used key device in pulsed power systems. As a difficult problem affecting the performance of the gas spark switch, electrode erosion has always been of wide concern and has been studied by scholars. In order to reduce electrode erosion, the erosion resistance of the electrode materials is particularly critical. At present, researchers at home and abroad mainly perform a large number of experiments to compare the erosion resistance of different electrode materials, which require a lot of time and are expensive. Based on the theoretical derivation of the erosion heat conduction process and the analysis of the molten pool movement process, a theoretical prediction model of erosion resistance of electrode materials is established in this paper. The prediction results of this model are consistent with the experimental results of most researchers in the past. In order to further verify the accuracy of this model, this paper selected six electrode materials [stainless steel, brass, RHEAs (Refractory High Entropy Alloys), 90WCu alloy, 70WCu alloy, and 50WCu alloy] tested for 10 000 times under the experimental conditions of a peak current of 30 kA, a single discharge charge transfer of 78 mC, and 2 bars dry air. The final experimental results show that the six electrode materials ranked from weak to strong in erosion resistance: brass, stainless steel, 50WCu, 70WCu, RHEAs, and 90WCu, which is consistent with the prediction results of the model.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Pulsed Power Technology Applications · Welding Techniques and Residual Stresses · Laser-Plasma Interactions and Diagnostics

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Materials Science and Engineering, Xiangtan University 1 , Xiangtan 411105, People’s Republic of China

State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology 2 , Xi’an 710024, People’s Republic of China

References (22)

Show source-provided references
1. 1990
2. 2006
3. Degradation of performance due to electrode erosion in field distortion gas switch in long-term repetitive operation10.1109/tps.2014.2313636 ↗
4. Ejection of electrode molten droplet and its effect on the degradation of insulator in gas spark switches10.1109/tps.2015.2408607 ↗
5. Surface studies of dielectric materials used in spark gaps10.1063/1.332857 ↗
6. Review of the mechanisms of electrode and insulator erosion and degradation in high current arc environments10.1109/20.364606 ↗
7. The effect of thermal conductivity upon the electrical erosion of metals
8. Electrode erosion in high-current, high-energy transient arcs
9. Influence of the current magnitude and working gas temperature on electrode erosion in the discharge chambers of high-power pulsed plasmatrons10.1134/s1063784207080087 ↗
10. Arc ablation behavior and microstructure evolution of plastically deformed and micro-alloyed Cu-Cr-Zr alloys10.1016/j.jallcom.2019.153123 ↗
11. Effect of the medium on the electrical erosion of electrodes at high currents
12. Effect of 100-nm Al2O3 particle inclusions on 100-kA pulsed arc erosion of W–Cu electrodes10.1109/tps.2019.2958681 ↗
13. A gap distance threshold in electrode erosion in high current, high energy spark gaps
14. 1988
15. Cohesion in alloys—Fundamentals of a semi empirical model10.1016/0378-4363(80)90054-6 ↗
16. 1988
17. 2004
18. Tungsten and its alloys
19. Material studies in a high energy spark gap10.1109/tps.1982.4316191 ↗
20. Electrode erosion and lifetime performance of a high repetition rate, triggered, corona-stabilized switch in air10.1088/0022-3727/33/9/309 ↗
21. Electrode erosion in spark discharges10.1063/1.1702586 ↗
22. Electrode erosion of a high energy impulse spark gap switch10.1088/1009-0630/7/6/021 ↗