A study on scattering correction for γ-photon 3D imaging test method
Source abstract
Abstract
A pair of 511KeV γ-photons is generated during a positron annihilation. Their directions differ by 180°. The moving path and energy information can be utilized to form the 3D imaging test method in industrial domain. However, the scattered γ-photons are the major factors influencing the imaging precision of the test method. This study proposes a γ-photon single scattering correction method from the perspective of spatial geometry. The method first determines possible scattering points when the scattered γ-photon pair hits the detector pair. The range of scattering angle can then be calculated according to the energy window. Finally, the number of scattered γ-photons denotes the attenuation of the total scattered γ-photons along its moving path. The corrected γ-photons are obtained by deducting the scattered γ-photons from the original ones. Two experiments are conducted to verify the effectiveness of the proposed scattering correction method. The results concluded that the proposed scattering correction method can efficiently correct scattered γ-photons and improve the test accuracy.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Medical Imaging Techniques and Applications · Radiation Detection and Scintillator Technologies · Nuclear Physics and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
College of Automation Engineering, Nanjing University of Aeronautics and Astronautics , Nanjing 211106, China
Funding
Jiangsu Province Youth Funding · NUAA Innovation Projects · NUAA Major Projects Foster Funding
References (18)
Show source-provided references
1. Simultaneous 68Ga-DOTATOC-PET/MRI for characterization of undetermined upper abdominal tracer uptake in 68Ga-DOTATOC PET/CT [J]
2. A positron injection-based 3D imaging method for inner cavities in complex parts [J]
3. A new method for spatial structure detection of complex inner cavities based on 3D γ-photon imaging [J]
4. 3D imaging of geometrical structure and defect location of inner cavity in aviation devices by positron injection [C]
5. Investigation of non-destructive testing in inner cavity with ant-nest structure based on positron annihilation [J]10.4028/www.scientific.net/ddf.373.61 ↗
6. Optimization of a fully 3D single scatter simulation algorithm for 3D PET [J]10.1088/0031-9155/49/12/008 ↗
7. Scatter correction with combined single-scatter simulation and Monte Carlo simulation for 3D PET[C]
8. PET energy-based scatter estimation and image reconstruction with energy-dependent correction [J]10.1088/0031-9155/51/11/016 ↗
9. Magnetic resonance imaging-Guided attenuation and scatter corrections in three-dimensional brain positron emission tomography [J]10.1118/1.1569270 ↗
10. Noise properties of four strategies for incorporation of scatter and attenuation information in PET reconstruction using the EM-ML algorithm [J]10.1109/tns.2006.880973 ↗
11. Nonstationary scatter subtraction-restoration in high-resolution PET [J]
12. Monte-Carlo simulation for scatter correction compensation studies in SPECT imaging using gate software package [J]10.1016/j.nima.2006.08.056 ↗
13. Monte Carlo simulation based scatter correction in 3D list-mode image reconstruction[C]
14. Parallelization of MLEM algorithm for PET reconstruction based on GPUs [C]
15. Improving the signal-to-noise ratio in static PET reconstruction using HYPR-OSEM[C]
16. Data acquisition in PET imaging [J]
17. Fast implementation of the single scatter simulation algorithm and its use in iterative image reconstruction of PET data [J]10.1088/0031-9155/47/16/310 ↗
18. Double Scatter Simulation using the Polarized Klein-Nishina formula[C]