Pulsed magnetic field generation suited for low-field unilateral nuclear magnetic resonance systems
Source abstract
Abstract
Pulsed magnetic fields can be used to provide instantaneous localized magnetic field variations. In presence of static fields, pulsed field variations are often used to apply torques and in-effect to measure behavior of magnetic moments in different states. In this work, the design and experimental performance of a pulsed magnetic field generator suited for low static field nuclear magnetic resonance (NMR) applications is presented. One of the challenges of low bias field NMR measurements is low signal to noise ratio due to the comparable nature of the bias field and the pulsed field. Therefore, a circuit is designed to apply pulsed currents through an inductive load, leading to generation of pulsed magnetic fields which can temporarily overpower the effect of the bias field on magnetic moments. The designed circuit will be tuned to operate at the precession frequency of 1H (protons) placed in a bias field produced by permanent magnets. The designed circuit parameters may be tuned to operate under different bias conditions. Therefore, low field NMR measurements can be performed for different bias fields. Circuit simulations were used to determine design parameters, corresponding experimental measurements will be presented in this work.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: NMR spectroscopy and applications · Advanced MRI Techniques and Applications · Advanced NMR Techniques and Applications
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Iowa State University , Ames, Iowa 50011, USA
Funding
IBM Fellowship Program
References (13)
Show source-provided references
1. 2015
2. 2011
3. 1981
4. Journal of Magnetic Resonance · 2017 · 282 · 10410.1016/j.jmr.2017.07.006 ↗
5. IEEE Transactions on Magnetics · 2017
6. Journal of Magnetic Resonance · 2013 · 231 · 7210.1016/j.jmr.2013.03.009 ↗
7. Journal of Magnetic Resonance (1969) · 1976 · 24 · 7110.1016/0022-2364(76)90233-x ↗
8. IEEE Transactions on Magnetics · 2014 · 50 · 110.1109/tmag.2014.2325796 ↗
9. IEEE Magnetics Letters · 2013 · 4 · 600010410.1109/lmag.2013.2250923 ↗
10. N. R. Bouda, “Methods of magnetic field switching for biomedical and power applications,” Ph.D. thesis, Iowa State University (2015).
11. IEEE Transactions on Magnetics · 2016 · 52 · 110.1109/tmag.2015.2514064 ↗
12. IEEE Journal of Solid-State Circuits · 2006 · 41 · 155110.1109/jssc.2006.873896 ↗
13. IEEE Transactions on Magnetics · 2014 · 50 · 110.1109/tmag.2014.2323336 ↗