journal article·2022-03-01Open access

Breakdown characteristics of combined air gaps under lightning impulse

Shaocheng Wu, Linong Wang, Jiachen Gao, Cheng Xie, Lei Liu, Tingting Wang, Enwen Li

AIP Advances· Volume 12· Issue 3

Abstract

With the increase of both voltage level and the transmission capacity, more attention has been paid to the external insulation of transmission lines. As the main external insulation medium of transmission line, the air gap’s dielectric strength will change when there are floating conductors. In this paper, we established an experiment platform to study the effects of floating conductors, simulated by floating rod electrode, on breakdown voltage, breakdown time, electric field distribution and discharge physical process of long air gaps under lightning impulse. The results showed that the intervention of floating electrode reduced the breakdown voltage and breakdown time of long air gaps, and the position with the longest breakdown time was the same as the position with the lowest breakdown voltage. In addition, the intervention of floating electrode improved the spatial electric field and complexity of discharge physical process.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: High voltage insulation and dielectric phenomena · Lightning and Electromagnetic Phenomena · Aerosol Filtration and Electrostatic Precipitation

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

School of Electrical Engineering and Automation, Wuhan University 1 , Wuhan 430000, China

Department of Electrical, Electronic and Information Engineering “Guglielmo Marconi”, University of Bologna 2 , Bologna 40136, Italy

Electric Power Research Institute, China Southern Power Grid 3 , Guangzhou 510000, China

Funding

Open Fund of National Engineering Laboratory for Ultra High Voltage Engineering Technology

References (31)

Show source-provided references
1. Bird streamer flashovers on FPL transmission lines10.1109/61.400832 ↗
2. Study on bird hazard prevention measure adopted in power transmission lines
3. P. Taylor, “Case study of bird streamer caused transient earth faults on a 275 kV transmission grid,” M.S. thesis, University of Natal Durban, Vryheid, 2001.
4. Influence of protrusions on the positive switching impulse breakdown voltage of sphere-plane air gaps in high-altitude areas10.1049/iet-smt.2019.0184 ↗
5. Breakdown characteristics of long air gap with negative polarity switching impulse10.1109/tdei.2013.003627 ↗
6. Experimental study on branch and diffuse type of streamers in leader restrike of long air gap discharge10.1088/1009-0630/18/3/15 ↗
7. On the use of quantitative Schlieren techniques in temperature measurement of leader discharge channels10.1088/1361-6595/ab1c3e ↗
8. Leader channel models for long air positive electrical discharges10.1016/j.elstat.2015.05.026 ↗
9. Modeling of positive switching impulse discharge of UHV transmission line air gaps10.3390/app8122594 ↗
10. A modified model for discharge voltage of AC transmission line-tower air gaps10.1109/access.2019.2919440 ↗
11. Switching impulse discharge characteristics of UHV transmission line air gaps10.1002/tee.22851 ↗
12. Engineering model of dielectric strength in phase-to-phase air gaps10.1049/iet-gtd.2020.0592 ↗
13. Modelling of dielectric strength in long air gaps: Application to a complex geometry10.1088/1361-6463/ab642c ↗
14. Discharge of air gaps during ground potential live-line work on transmission lines10.1016/j.epsr.2020.106519 ↗
15. Switching impulse strength of air gaps containing a metallic body at floating potential
16. Floating potential bodies and their interaction with discharge development
17. A study of bird streamer initiated breakdown characteristics under HVDC conditions
18. Effect of floating conducting objects on critical switching impulse breakdown of air insulation10.1109/61.400917 ↗
19. Flashover performance of a rod-rod gap containing a floating rod under switching impulses with critical and near critical times to crest
20. Research on live working on 500 kV compact transmission lines in high altitude area10.13336/j.1003-6520.hve.2005.08.005 ↗
21. Research of minimum approach distance for live working on 750 kV AC transmission lines10.13336/j.1003-6520.hve.2007.11.042 ↗
22. Research on minimum approach distance for live working on 1000 kV AC transmission line10.13336/j.1003-6520.hve.2006.12.019 ↗
23. Simulation method for discharge characteristics of live working complex gap10.13336/j.1003-6520.hve.20180329032 ↗
24. Study on the discharge characteristics of combined air gap with floating potential conductor under DC high voltage
25. Experimental study on discharge characteristics of combined air gap with floating potential conductor10.13296/j.1001-1609.hva.2018.04.001 ↗
26. Effect of a floating conductor on discharge characteristics of a long air gap under switching impulse10.1016/j.elstat.2021.103629 ↗
27. 2010
28. Impulse discharge voltage prediction of air gaps10.1007/978-981-10-5163-0_6 ↗
29. Breakdown process on rod–rod air gap under oscillating lightning impulse voltage10.1049/hve.2019.0281 ↗
30. Discharge process on long rod-rod electrodes under positive lightning impulse voltage
31. Numerical modeling of electrical discharges in long air gaps tested with positive switching impulses10.1109/tps.2018.2802039 ↗