Enhanced radiation hardness and signal recovery in thin diamond detectors
Source abstract
Abstract
Using the advantage of the high spatial resolution of the Ruđer Bošković Institute (RBI) ion microprobe, small areas of a thin membrane single crystal chemical vapor deposition (scCVD) diamond detector were intentionally damaged with a high-intensity 26-MeV oxygen ion beam at various fluences, producing up to ∼1018 vacancies/cm3. The response of the detector was tested with the ion beam-induced charge technique (IBIC) using a 2-MeV proton beam as a probe. The signal amplitudes decreased down to approximately 50% of the original value at low electric fields (<10 V/μm) inside the detector. However, the increase of electric field to values of ∼100 V/μm completely recovers the signal amplitude. The results presented herein can facilitate the development of true radiation hard particle detectors.
Source: crossref · Quality: baseline
Research context
OpenAlex topics: Diamond and Carbon-based Materials Research · Ion-surface interactions and analysis · High-pressure geophysics and materials
SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.
Affiliations
Division of Experimental Physics, Ruđer Bošković Institute 1 , 10000 Zagreb, Croatia
CEA-LIST, Diamond Sensors Laboratory 2 , Gif-sur-Yvette F 91191, France
Division of Electronics and Informatics, Faculty of Science and Technology, Gunma University 3 , Kiryu, Gunma 376-8515, Japan
Funding
European Regional Development Fund
References (11)
Show source-provided references
1. Appl. Phys. Lett. · 2013 · 103 · 24310610.1063/1.4833236 ↗
2. Appl. Phys. Lett. · 2016 · 109 · 04350210.1063/1.4959863 ↗
3. IEEE Trans Nucl Sci · 2018 · 65 · 158310.1109/TNS.2018.2797540 ↗
4. JINST · 2017 · 12 · C0205610.1088/1748-0221/12/02/C02056 ↗
5. Radiation hardness of diamond and silicon sensors compared10.1002/pssa.200776327 ↗
6. Appl. Phys. Lett. · 2013 · 103 · 11210610.1063/1.4821035 ↗
7. Nucl. Instrum. Methods Phys. Res. B · 2010 · 268 · 181810.1016/j.nimb.2010.02.091 ↗
8. Nucl. Instrum. Methods Phys. Res. B · 2007 · 260 · 11410.1016/j.nimb.2007.01.252 ↗
9. A review of ion beam induced charge microscopy10.1016/j.nimb.2007.09.031 ↗
10. S. Muller, PhD Thesis, “The beam condition monitor 2 and the radiation environment of the CMS detector at the LHC,” CERN 2010, https://inspirehep.net/record/886902/files/CERN-THESIS-2010-175.pdf.
11. Development of single-crystal CVD-diamond detectors for spectroscopy and timing10.1002/pssa.200671127 ↗