journal article·2016-02-01Open access

Ultrasound (US) transducer of higher operating frequency detects photoacoustic (PA) signals due to the contrast in elastic property

Mayanglambam Suheshkumar Singh, Huabei Jiang

AIP Advances· Volume 6· Issue 2

Abstract

We report our study that shows selection in operating frequency of US-transducer used for boundary detection of PA-signals, which result due to the contrast in elastic property distribution (E(r→)) in sample material other than that of optical absorption coefficient (μa). Studies were carried out, experimentally, in tissue-mimicking Agar phantoms employing acoustic resolution photoacoustic microscopy (AR-PAM) system as an imaging unit. In the experiments, various transducers having different operating frequencies, ranging from 1MHz to 50MHz, were employed for studying frequency response of the photoacoustic signals. The study shows that, for detecting photoacoustic signals due to the contrast in elastic property, ultrasound transducer with higher operating frequency (∼50MHz) is demanded.
Source: crossref · Quality: baseline

Research context

OpenAlex topics: Photoacoustic and Ultrasonic Imaging · Ultrasound Imaging and Elastography · Optical Imaging and Spectroscopy Techniques

SciVX discovery tags are terminology-based. OpenAlex topics are source-provided classifications.

Affiliations

Indian Institute of Science Education & Research (IISER) 1 School of Physics, , Thiruvananthapuram, Kerala, India -695016

University of Florida (UF) 2 Department of Biomedical Engineering, , Gainesville, Florida (FL), USA -32611

Funding

IISER-TVM start-up grant

References (16)

Show source-provided references
1. Opts. Lett. · 2014 · 39 · 397010.1364/OL.39.003970 ↗
2. Amer. J. Sc. · 1880 · 20 · 30510.2475/ajs.s3-20.118.305 ↗
3. Nat. · 1880 · 22 · 50010.1038/022500a0 ↗
4. Sc. Reps. · 2014 · 4 · 587810.1038/srep05878 ↗
5. J. Ultras. Med. · 2005 · 24 · 98510.7863/jum.2005.24.7.985 ↗
6. Ultrason. Imag. · 1998 · 20 · 26010.1177/016173469802000403 ↗
7. Biophys. J. · 2010 · 98 · 205310.1016/j.bpj.2009.12.4317 ↗
8. J. Biomed. Opts. · 2009 · 14 · 05402410.1117/1.3247155 ↗
9. Proc. SPIE · 2009 · 7177 · 71771310.1117/12.806788 ↗
10. Appl. Phys. Lett. · 2012 · 101 · 01370210.1063/1.4732797 ↗
11. Appl. Phys. Lett. · 2014 · 104 · 25370110.1063/1.4881264 ↗
12. IEEE Trans. Ultras. Ferro. Freq. Cont. · 1997 · 44 · 135510.1109/58.656639 ↗
13. Phys. Med. Biol. · 1997 · 42 · 197110.1088/0031-9155/42/10/011 ↗
14. Phys. Med. Biol. · 2006 · 51 · 558110.1088/0031-9155/51/21/013 ↗
15. Biophysical bases of elasticity imaging10.1007/978-1-4615-1943-0_23 ↗
16. Proc. IEEE · 2003 · 91 · 150310.1109/JPROC.2003.817865 ↗